The Reliability of Fatmax
Authors:
- 17 March 2009
- journal article
- Published by Wiley in Scandinavian Journal of Medicine & Science in Sports
- Vol. 19 (2) , 213-221
Abstract
The exercise intensity eliciting maximal fat oxidation (Fatmax) is typically determined during an incremental test. Its reproducibility, however, has not been thoroughly investigated so far. To address this issue, 21 healthy subjects (23.5±1.7 years; BMI 22.4±1.8 kg/m2; VO2peak 47.4±11.3 mL/min/kg) carried out two identical cycling tests to determine Fatmax after an initial incremental baseline test. The duration of each of five stages during the Fatmax tests was 6 min. The first stage equalled the first increase in blood lactate during the baseline test; the highest stage corresponded to a respiratory exchange ratio of 1.00. Between these intensities the other three stages were distributed evenly. Fatmax was 28.0±8.6 L/min (59.2±18.1% VO2peak) in the first test and 29.8±10.5 L/min (62.9±22.2% VO2peak) in the second one. There was no significant difference between both Fatmax determinations [number of stage: P=0.31; total VO2: P=0.20; VO2 utilized for fat oxidation (VO2Fat): P=0.33]. Linear correlation coefficients between tests were r=0.84 (total VO2; Pr=0.83 (VO2Fat; P2) and 0.32 L/min (VO2Fat). In conclusion, spontaneous intraindividual variability in Fatmax appears too large to recommend the use of this parameter for the prescription of training intensity.Keywords
This publication has 19 references indexed in Scilit:
- Determination of “Fatmax” with 1 h cycling protocols of constant loadApplied Physiology, Nutrition, and Metabolism, 2007
- Comparison of the Type of Substrate Oxidation During Exercise Between Pre and Post Pubertal Markedly Obese BoysInternational Journal of Sports Medicine, 2006
- A Conceptual Framework for Performance Diagnosis and Training Prescription from Submaximal Gas Exchange Parameters - Theory and ApplicationInternational Journal of Sports Medicine, 2004
- Reliability of Gas Exchange Measurements from Two Different Spiroergometry SystemsInternational Journal of Sports Medicine, 2001
- The effects of increasing exercise intensity on muscle fuel utilisation in humansThe Journal of Physiology, 2001
- Validation of a Computerized Metabolic Measurement System (Oxycon-Pro®) During Low and High Intensity Exercise1International Journal of Sports Medicine, 2001
- Oxygen Uptake Kinetics During ExerciseSports Medicine, 1999
- Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports MedicineSports Medicine, 1998
- Validity and Reliability of the Cosmed K2 InstrumentInternational Journal of Sports Medicine, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986