Step Sequence and Direction Detection of Four Square Step Test
Open Access
- 6 July 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 2 (4) , 2194-2200
Abstract
Poor balance control and falls are big issues for older adults that due to aging decline have a lower postural balance and directional control in balance performance than younger age groups. The four square step test (FSST) was developed to evaluate rapid stepping that is often required when changing direction and avoiding obstacles while walking. However, previous researchers used only the total time as the assessment in the test. The aim of this paper is to objectively quantify the sequence and direction of the steps in FSST, by using two inertial sensors placed on both feet. An algorithm was developed to automatically segment the steps performed during the test, and calculate the stepping direction from the linear velocity of the foot. Experiments were conducted with 100 Japanese healthy older adults, where sensor data and video of 20 subjects were randomly subtracted for algorithm verification. The results showed that the algorithm succeeded for 71.7% trials in recognizing both the step sequence and step direction in FSST, while 90.2% of the detection failure could be excluded with an auto verification method.Keywords
Funding Information
- JSPS Grant-in-Aid for Young Scientists (Wakate B) (25750259, 15K21437)
- Program for Leading Graduate Schools
- Graduate Program for Embodiment Informatics” of the Ministry of Education, Culture, Sports, Science and Technology
- UK-HEFCE
- LU-EESE
This publication has 15 references indexed in Scilit:
- Fear of falling and activities of daily living function: mediation effect of dual-task abilityAging & Mental Health, 2017
- A Novel Pedestrian Navigation Algorithm for a Foot-Mounted Inertial-Sensor-Based SystemSensors, 2016
- Age‐related differences in dual task performance: A cross‐sectional study on womenGeriatrics & Gerontology International, 2015
- Accuracy of the Microsoft Kinect™ for measuring gait parameters during treadmill walkingGait & Posture, 2015
- Walking assessment in the phase space by using ultra-miniaturized Inertial Measurement Units2013
- A comparison of Pedestrian Dead-Reckoning algorithms using a low-cost MEMS IMU2009
- Balance disorders in the elderlyNeurophysiologie Clinique, 2008
- The Four Square Step Test is a Feasible and Valid Clinical Test of Dynamic Standing Balance for Use in Ambulant People PoststrokeArchives of Physical Medicine and Rehabilitation, 2008
- Assessment of Walking Features From Foot Inertial SensingIEEE Transactions on Biomedical Engineering, 2005
- A clinical test of stepping and change of direction to identify multiple falling older adultsArchives of Physical Medicine and Rehabilitation, 2002