Polyurethane-based microfluidic devices for blood contacting applications
- 5 January 2012
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (5) , 960-970
Abstract
Protein adsorption on PDMS surfaces poses a significant challenge in microfluidic devices that come into contact with biofluids such as blood. Polyurethane (PU) is often used for the construction of medical devices, but despite having several attractive properties for biointerfacing, it has not been widely used in microfluidic devices. In this work we developed two new fabrication processes for making thin, transparent and flexible PU-based microfluidic devices. Methods for the fabrication and bonding of microchannels, the integration of fluidic interconnections and surface modification with hydrophilic polyethylene oxide (PEO) to reduce protein adsorption are detailed. Using these processes, microchannels were produced having high transparency (96% that of glass in visible light), high bond strength (326.4 kPa) and low protein adsorption (80% reduction in fibrinogen adsorption vs. unmodified PDMS), which is critical for prevention of fouling. Our findings indicate that PEO modified PU could serve as an effective alternative to PDMS in blood contacting microfluidic applications.Keywords
This publication has 80 references indexed in Scilit:
- Reusable, adhesiveless and arrayed in-plane microfluidic interconnectsJournal of Micromechanics and Microengineering, 2011
- A silicone-based microfluidic chip grafted with carboxyl functionalized hyperbranched polyglycerols for selective protein captureMicrofluidics and Nanofluidics, 2009
- Integrating polyurethane culture substrates into poly(dimethylsiloxane) microdevicesBiomaterials, 2009
- Nonfouling Characteristics of Dextran-Containing SurfacesLangmuir, 2006
- A photochemical method for the surface modification of poly(etherurethanes) with phosphorylcholine-containing compounds to improve hemocompatibilityJournal of Biomedical Materials Research, 1997
- Blood compatibility of PEO grafted polyurethane and HEMA/styrene block copolymer surfacesJournal of Biomedical Materials Research, 1990
- Microphase separated structure, surface composition and blood compatibility of segmented poly(urethaneureas) with various soft segment componentsPolymer, 1985
- Adsorption of proteins from plasma to a series of hydrophilic‐hydrophobic copolymers. I. Analysis with the in situ radioiodination techniqueJournal of Biomedical Materials Research, 1981
- Polyurethane Elastomers in SurgeryInternational Journal of Polymeric Materials and Polymeric Biomaterials, 1977
- Development of block copolyether‐urethane intra‐aortic balloons and other medical devicesJournal of Biomedical Materials Research, 1973