Intradermal Lactate Monitoring Based on a Microneedle Sensor Patch for Enhanced In Vivo Accuracy
Open Access
- 22 May 2024
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (6) , 3115-3125
Abstract
Lactate is an important diagnostic and prognostic biomarker of several human pathological conditions, such as sepsis, malaria, and dengue fever. Unfortunately, due to the lack of reliable analytical decentralized platforms, the determination of lactate yet relies on discrete blood-based assays, which are invasive and inefficient and may cause tension and pain in the patient. Herein, we demonstrate the potential of a fully integrated microneedle (MN) sensing system for the minimally invasive transdermal detection of lactate in an interstitial fluid (ISF). The originality of this analytical technology relies on: (i) a strategy to provide a uniform coating of a doped polymer-based membrane as a diffusion-limiting layer on the MN structure, optimized to perform full-range lactate detection in the ISF (linear range of response: 0.25–35 mM, 30 s assay time, 8 h operation), (ii) double validation of ex vivo and in vivo results based on ISF and blood measurements in rats, (iii) monitoring of lactate level fluctuations under the administration of anesthesia to mimic bedside clinical scenarios, and (iv) in-house design and fabrication of a fully integrated and portable sensing device in the form of a wearable patch including a custom application and user-friendly interface in a smartphone for the rapid, routine, continuous, and real-time lactate monitoring. The main analytical merits of the lactate MN sensor include appropriate selectivity, reversibility, stability, and durability by using a two-electrode amperometric readout. The ex-vivo testing of the MN patch of preconditioned rat skin pieces and euthanized rats successfully demonstrated the accuracy in measuring lactate levels. The in vivo measurements suggested the existence of a positive correlation between ISF and blood lactate when a lag time of 10 min is considered (Pearson’s coefficient = 0.85, mean difference = 0.08 mM). The developed MN-based platform offers distinct advantages over noncontinuous blood sampling in a wide range of contexts, especially where access to laboratory services is limited or blood sampling is not suitable. Implementation of the wearable patch in healthcare could envision personalized medicine in a variety of clinical settings.Keywords
Funding Information
- Vetenskapsr?det (VR-2019-04142)
- Carl Tryggers Stiftelse f?r Vetenskaplig Forskning (CTS 20:88)
- Olle Engkvists Stiftelse (204-0214)
- China Scholarship Council
This publication has 48 references indexed in Scilit:
- Recent Progress in Microneedles‐Mediated Diagnosis, Therapy, and Theranostic SystemsAdvanced Healthcare Materials, 2022
- In vitro and in vivo detection of lactate with nanohybrid-functionalized Pt microelectrode facilitating assessment of tumor developmentBiosensors and Bioelectronics, 2021
- Minimally‐invasive Microneedle‐based Biosensor Array for Simultaneous Lactate and Glucose Monitoring in Artificial Interstitial FluidElectroanalysis, 2019
- Microneedle-based biosensor for minimally-invasive lactate detectionBiosensors and Bioelectronics, 2019
- Silicon/SU8 multi-electrode micro-needle for in vivo neurochemical monitoringBiosensors and Bioelectronics, 2015
- Preanesthesia, Anesthesia, Analgesia, and Euthanasia2015
- Elastic modulus and viscoelastic properties of full thickness skin characterised at micro scalesBiomaterials, 2013
- Handbook of Reference Electrodes2013
- Microdialysis-assessed interstitium alterations during sepsis: relationship to stage, infection, and pathogenIntensive Care Medicine, 2011
- The viscoelastic, hyperelastic and scale dependent behaviour of freshly excised individual skin layersBiomaterials, 2011