Optimal ablation settings of TactiFlex SE laser-cut irrigated-tip catheter: comparison with ThermoCool SmartTouch SurroundFlow porous irrigated-tip catheter
- 4 April 2024
- journal article
- research article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 67 (8) , 1755-1769
Abstract
Background The TactiFlex SE catheter (TFSE, Abbott) with a contact force (CF) sensor and a laser-cut irrigated-tip has recently become available but lacks a lesion quality marker. This study aimed to explore distinctions in lesion characteristics between the TFSE and the ThermoCool SmartTouch SurroundFlow catheter (STSF, Biosense Webster), which utilizes a porous irrigated tip, and to assess the most effective application settings for the TFSE. Methods Lesions were generated using varying settings of radiofrequency power (30–50 W), CF (10–20 g), application duration (10–40 s), and catheter orientation (perpendicular or parallel) in an ex vivo porcine model. Comparative analysis between the TFSE and STSF was conducted for lesion characteristics and incidence of steam pops using predictive models in regression analyses. Results Among 720 applications, the TFSE exhibited a significantly lower incidence of steam pops compared to the STSF (0.6% vs. 36.8%, P < 0.001). Moreover, coefficients of determination (R2) for the TFSE were higher than those for the STSF concerning lesion depth (0.710 vs. 0.541) and volume (0.723 vs. 0.618). The lesion size generated with the TFSE was notably smaller than that with the STSF under identical application settings. Additionally, to achieve a lesion depth ≥ 4.0 mm, the TFSE required an application duration 8–12 s longer than the STSF under similar settings. Conclusions The TFSE demonstrated a lower incidence of steam pops and superior predictability in lesion size compared to the STSF. However, the TFSE necessitated a longer application duration than the STSF to achieve an adequate lesion size. Graphical AbstractKeywords
This publication has 20 references indexed in Scilit:
- Detailed investigation of the lesion formation with a novel contact force sensing catheter with a mesh‐shaped irrigation tipJournal of Arrhythmia, 2023
- Personalized paroxysmal atrial fibrillation ablation by tailoring ablation index to the left atrial wall thickness: the ‘Ablate by-LAW’ single-centre study—a pilot studyEP Europace, 2021
- JCS/JHRS 2019 guideline on non‐pharmacotherapy of cardiac arrhythmiasJournal of Arrhythmia, 2021
- Randomized study defining the optimum target interlesion distance in ablation index-guided atrial fibrillation ablationEP Europace, 2020
- Temperature-Controlled Radiofrequency Ablation Using Irrigated CathetersJACC: Clinical Electrophysiology, 2020
- Role of Contact Force Sensing in Catheter Ablation of Cardiac ArrhythmiasJACC: Clinical Electrophysiology, 2018
- Evaluation of a Strategy Aiming to Enclose the Pulmonary Veins With Contiguous and Optimized Radiofrequency Lesions in Paroxysmal Atrial FibrillationJACC: Clinical Electrophysiology, 2018
- 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillationEP Europace, 2017
- In Vitro Validation of the Lesion Size Index to Predict Lesion Width and Depth After Irrigated Radiofrequency Ablation in a Porcine ModelJACC: Clinical Electrophysiology, 2017
- Saline‐Irrigated Radiofrequency Ablation Electrode with External CoolingJournal of Cardiovascular Electrophysiology, 2005