Axial Compressive Performance of a Composite Concrete-Filled GFRP Tube Square Column
Open Access
- 23 July 2021
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 11 (15) , 6757
Abstract
A composite concrete-filled glass fiber reinforced polymer (GFRP) tube square column is a new type of composite column, where GFRP is externally wrapped over several GFRP square tubes to form a multicavity GFRP tube, and then concrete is poured inside. External GFRP wrapping methods can be divided into two types: entirely wrapped and strip-type wrapped methods. The former is superior to the latter in terms of performance under stress. However, difficulties are introduced in the construction process of the former, and substantial materials are required to wrap the entire structure. To examine the axial compressive performance for this new type of composite column and the impact of the wrapping method, we designed and fabricated one type of entirely wrapped composite column and two types of strip-type wrapped composite columns with clear spacings of 85 mm and 40 mm, respectively, and performed static axial compression tests. Through tests and numerical simulations, we obtained the failure mode, load–displacement curve, and load–strain curve of the specimen, and analyzed the impact of the externally wrapped GFRP on the mechanical behavior of the composite column. The results show that the composite column reached the peak load before the fracture of the GFRP tube fiber occurred, and the bearing capacity declined sharply to approximately 75% of the peak load after the fiber fractured, then entered a platform section, thereby displaying ductile failure. As the wrapped layers of GFRP strips increased, the load capacity of the specimen exhibited a linear growth tendency. Compared with the performance of the entirely wrapped method, the load capacity of the specimens in the W5040 group declined 9.8% on average, and the peak efficiency of the GFRP strips increased by 50%, thereby indicating that the use of appropriate GFRP layers and strip distance intervals can ensure the appropriate bearing capacity of composite columns and full utilization of GFRP material properties.Keywords
Funding Information
- Study on Restraint Mechanism and Mechanical Behavior of a New Type of Pull Extruded Multi - Cavity Composite Pipe - Concrete Composite Column (51778286)
This publication has 22 references indexed in Scilit:
- Compressive Strength Testing of Hybrid Concrete-Filled Fiber-Reinforced Plastic Tubes Confined by Filament WindingApplied Sciences, 2021
- Comparative Investigation on Tensile Performance of FRP Bars after Exposure to Water, Seawater, and Alkaline SolutionsJournal of Materials in Civil Engineering, 2020
- Discontinuous FRP-Confinement of Masonry ColumnsFrontiers in Built Environment, 2020
- Experimental evaluation of seismic performance of interior RC beam-column joints strengthened with FRP compositesEngineering Structures, 2019
- Compressive Behavior of Composite Concrete Columns with Encased FRP Confined Concrete CoresSensors, 2019
- Behaviour of Hybrid Steel and FRP-Reinforced Concrete—ECC Composite Columns under Reversed Cyclic LoadingSensors, 2018
- Long term performance and fire safety aspect of FRP composites used in building structuresConstruction and Building Materials, 2016
- Characterisation of the mechanical properties of pultruded fibre-reinforced polymer tubeMaterials & Design (1980-2015), 2014
- Confinement Effectiveness in Rectangular Concrete Columns with Fiber Reinforced Polymer WrapsJournal of Composites for Construction, 2005
- In-service performance of glass reinforced plastic composites in buildingsProceedings of the Institution of Civil Engineers - Structures and Buildings, 2004