Comparison of linear measurements made from storage phosphor and dental radiographs.
Authors:
- C F HildeboltCHC F Hildebolt
- N Yokoyama-CrothersNYN Yokoyama-Crothers
- 1 November 1996
- journal article
- research article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 25 (5) , 268-273
Abstract
To compare linear measurements made from storage phosphor and dental radiographs. Five dry hemimandibles were imaged with an 8 x 10-inch (20.3/25.4 cm) high-resolution storage phosphor plate and Ektaspeed Plus occlusal-size dental film. Optimal exposure was empirically determined for the dental films. Reductions in exposure of 50 and 75% were used for the storage phosphor. Three observers made linear measurements between end-points of lines and center-points of fiducials on clinical specimens, dental radiographs, digitized dental radiographs and storage phosphor images. Data were analysed with repeated-measures and nested analysis of variance. Measurements obtained from optimally exposed dental films and reduced-exposure storage phosphor images were equivalent to clinical measurements recorded from dry hemimandibles. Less than 2% of variation among measurements was attributable to the five modalities. No substantive difference was detected between linear measurements obtained from the storage phosphor or dental radiographis. Because storage phosphor images require no chemical processing, can be used at reduced exposure and are inherently digital, they are a viable alternative to dental film for making linear measurements.Keywords
This publication has 9 references indexed in Scilit:
- Anthropometric Optical Surface Imaging System Repeatability, Precision, and ValidationAnnals of Plastic Surgery, 1995
- Chest imaging within the radiology department by means of photostimulable phosphor computed radiography: A reviewJournal of Digital Imaging, 1992
- Clinical Experience in the Use of Photostimulable Phosphor Radiographic SystemsInvestigative Radiology, 1991
- Comparison of digital and conventional musculoskeletal radiography: observer performance study.Radiology, 1990
- Comparison of digital and conventional musculoskeletal radiography: an observer performance study.Radiology, 1990
- Clinical assessment of phosphor-plate computed radiography: Equipment, strategy, and methodsJournal of Digital Imaging, 1989
- Computed radiography utilizing laser-stimulated luminescence: Detectability of simulated low-contrast radiographic objectsComputerized Medical Imaging and Graphics, 1988
- Computed radiography utilizing scanning laser stimulated luminescence.Radiology, 1983
- An Extension of Box's Results on the Use of the $F$ Distribution in Multivariate AnalysisThe Annals of Mathematical Statistics, 1958