Atrial pacing to estimate total sinoatrial conduction time in children
Authors:
- Macdonald DickMDMacdonald Dick
- 1 June 1988
- journal article
- research article
- Published by Springer Nature in Pediatric Cardiology
- Vol. 9 (2) , 85-89
Abstract
No data exist concerning the total sinoatrial conduction time (TSACT) in children that compare values determined by the atrial extrastimulation technique (TSACTS) with those generated by the atrial pacing method (TSACTN). In this study, TSACT in 55 patients, age 0.2–18.5, was measured using both techniques. TSACTN was performed at a mean 90% (TSACTN−90) (n=32) or a mean 95% (TSACTN−95 and (n=38) of sinus cycle length (SCL). When data generated during determination of TSACTN−90 and TSACTS were compared, SCL and recovery cycle length (REC) were similar for both techniques. Likewise, TSACTS (128±40 ms) and TSACTN−90 (126±74 ms) were not significantly different. Coefficient of correlation wasr=0.82,pS and TSACTN−90. In contrast, when values generated during TSACTN−95 and TSACTS were compared, TSACTS exceeded TSACTN−95 (137±38 vs 105±58 ms;pr=0.82,pN−90 and TSACTS, individual differences in magnitude and direction were noted between the two techniques. In summary, TSACTN−90 approximates TSACTS in children. TSACTN−90 is preferable to TSACTN−95, probably due to more complete sinus node capture during atrial pacing. However, the behavior of the sinus node in response to extrastimuli (single or train) precludes favoring one technique over the other. More precise evaluation of sinoatrial conduction will require direct recording of sinus node activity.Keywords
This publication has 14 references indexed in Scilit:
- New application of direct sinus node recordings in man: assessment of sinus node recovery time.Circulation, 1984
- Cardiac Arrhythmias in ChildrenAnnual Review of Medicine, 1984
- The sinus node electrogram in patients with and without sick sinus syndrome: techniques and correlation between directly measured and indirectly estimated sinoatrial conduction time.Circulation, 1982
- Electrophysiologic residua and sequelae of surgery for congenital heart defectsThe American Journal of Cardiology, 1982
- Method for recording electrical activity of the sinoatrial node and automatic atrial foci during cardiac catheterization in human subjectsThe American Journal of Cardiology, 1980
- The estimation of sinoatrial conduction time in rabbit heart by the constant atrial pacing technique.Circulation, 1979
- Comparative study of two methods of estimating sinoatrial conduction time in manThe American Journal of Cardiology, 1978
- A new method for measurement of sinoatrial conduction time.Circulation, 1978
- Electrophysiologic evaluation of sinus node function in patients with sinus node dysfunction.Circulation, 1976
- Change of Cardiac Rhythm in the Rabbit after an Atrial Premature BeatCirculation Research, 1969