A review of workplace aerosol sampling procedures and their relevance to the assessment of beryllium exposures
Author:
- 1 January 2006
- journal article
- review article
- Published by Royal Society of Chemistry (RSC) in Journal of Environmental Monitoring
- Vol. 8 (6) , 598-604
Abstract
Standardized conventions governing the fractions of airborne particles that can penetrate the human head airways, the thoracic airways and the alveolar spaces have been internationally (although not universally) adopted. Several agencies involved in setting limit values for occupational exposure concentrations have taken these conventions into account when considering the appropriate standard for specific chemicals, in order to ensure the standards are biologically relevant. A convention is selected based on the characteristic health effects, and forms the basis of measurement against the limiting concentration value. In order to assess exposure for comparison to this metric or any other purposes, it is necessary to choose a sampler whose performance matches the convention, and protocols have been developed and used to test sampler performance. Several aerosol sampling devices are available, nominally at least, for each of the conventions. Some considerations important to the sampling of airborne particles containing beryllium with regard to the sampling conventions, the test protocols and sampler performance are discussed.Keywords
This publication has 30 references indexed in Scilit:
- A comparison of portable XRF and ICP-OES analysis for lead on air filter samples from a lead ore concentrator mill and a lead-acid battery recyclerJournal of Environmental Monitoring, 2006
- A comparison of X-ray fluorescence and wet chemical analysis of air filter samples from a scrap lead smelting operation2004
- Characterization of physicochemical properties of beryllium aerosols associated with prevalence of chronic beryllium diseaseJournal of Environmental Monitoring, 2004
- Study of fifteen respirable aerosol samplers used in occupational hygieneAnnals of Occupational Hygiene, 2001
- Inhalable Aerosol SamplersApplied Occupational and Environmental Hygiene, 1998
- Aerosol Instrumentation in Occupational Hygiene: An Historical PerspectiveAerosol Science and Technology, 1998
- Historical Perspectives: Realization, Development, and First Applications of the Personal Air SamplerApplied Occupational and Environmental Hygiene, 1997
- Investigation into the impact of introducing workplace aerosol standards based on the inhalable fractionThe Analyst, 1996
- New aerosol sampler with low wind sensitivity and good filter collection uniformityAtmospheric Environment, 1995
- INTERNAL WALL LOSSES OF PHARMACEUTICAL DUCTS DURING CLOSED-FACE, 37-MM POLYSTYRENE CASSETTE SAMPLINGAIHA Journal, 1991