Highly Reproducible Secondary Electron Imaging under Electron Irradiation Using High-Pass Energy Filtering in Low-Voltage Scanning Electron Microscopy
Authors:
- 27 February 2012
- journal article
- research article
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 18 (2) , 385-389
Abstract
The reproducibility of contrast in secondary electron (SE) imaging during continuous electron irradiation, which caused surface contamination, was investigated using SE high-pass energy filtering in low-voltage scanning electron microscopy (SEM). According to high-pass energy-filtered imaging, dopant contrast in an indium phosphide remained remarkably stable during continuous electron irradiation although the contrast in unfiltered SE images decreased rapidly as a contamination layer was formed. Charge neutralization and the SE energy distributions indicate that the contamination layer induces a positive charge. This results in a decrease of low-energy SE emissions and reduced dopant contrast in unfiltered SE images. The retention of contrast was also observed in high-pass energy-filtered images of a gold surface. These results suggest that this imaging method can be widely used when SE intensities decrease under continuous electron irradiation in unfiltered SE images. Thus, high-pass energy-filtered SE imaging will be of a great assistance for SEM users in the reproducibility of contrast such as a quantitative dopant mapping in semiconductors.Keywords
This publication has 19 references indexed in Scilit:
- Energy selective scanning electron microscopy to reduce the effect of contamination layers on scanning electron microscope dopant mappingUltramicroscopy, 2010
- Energy-filtered imaging in a scanning electron microscope for dopant contrast in InPJournal of Electron Microscopy, 2010
- The effect of oxidation and carbon contamination on SEM dopant contrastJournal of Physics: Conference Series, 2010
- The Effect of Oxide Overlayers on Secondary Electron Dopant MappingMicroscopy and Microanalysis, 2009
- Why is it possible to detect doped regions of semiconductors in low voltage SEM: a review and updateSurface and Interface Analysis, 2005
- Effect of experimental parameters on doping contrast of Si p?n junctions in a FEG-SEMMicroelectronic Engineering, 2004
- Deactivation and diffusion of boron in ion-implanted silicon studied by secondary electron imagingApplied Physics Letters, 1999
- Secondary electron imaging as a two-dimensional dopant profiling technique: Review and updateJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena, 1998
- Secondary electron emission in the scanning electron microscopeJournal of Applied Physics, 1983
- Electron beam induced potential contrast on unbiased planar transistorsSolid-State Electronics, 1967