Posterior Spinal Fusion Using Pedicle Screws
Authors:
- Andreas F. MavrogenisAMAndreas F. Mavrogenis
- George TriantafyllopoulosGTGeorge Triantafyllopoulos
- Spiros KoufosSKSpiros Koufos
- Spiros G. PneumaticosSPSpiros G. Pneumaticos
- 1 July 2013
- journal article
- Published by SLACK, Inc. in Orthopedics
- Vol. 36 (7) , e951-7
Abstract
Few clinical studies have reported polyetheretherketone (PEEK) rod pedicle screw spinal instrumentation systems (CD-Horizon Legacy PEEK rods; Medtronic, Minneapolis, Minnesota). This article describes a clinical series of 52 patients who underwent posterior spinal fusion using the PEEK Rod System between 2007 and 2010. Of the 52 patients, 25 had degenerative disk disease, 10 had lateral recess stenosis, 6 had degenerative spondylolisthesis, 6 had lumbar spine vertebral fracture, 4 had combined lateral recess stenosis and degenerative spondylolisthesis, and 1 had an L5 giant cell tumor. Ten patients had 1-segment fusion, 29 had 2-segment fusion, and 13 had 3-segment fusion. Mean follow-up was 3 years (range, 1.5–4 years); no patient was lost to follow-up. Clinical evaluation was performed using the Oswestry Disability Index and a low back and leg visual analog pain scale. Imaging evaluation of fusion was performed with standard and dynamic radiographs. Complications were recorded. Mean Oswestry Disability Index scores improved from 76% preoperatively (range, 52%–90%) to 48% at 6 weeks postoperatively, and to 34%, 28%, and 30% at 3, 6, and 12 months postoperatively, respectively. Mean low back and leg pain improved from 8 and 9 points preoperatively, respectively, to 6 and 5 points immediately postoperatively, respectively, and to 2 points each thereafter. Imaging union of the arthrodesis was observed in 50 (96%) patients by 1-year follow-up. Two patients sustained screw breakage: 1 had painful loss of sagittal alignment of the lumbar spine and underwent revision spinal surgery with pedicle screws and titanium rods and the other had superficial wound infection and was treated with wound dressing changes and antibiotics for 6 weeks. No adjacent segment degeneration was observed in any patient until the time of this writing.Keywords
This publication has 48 references indexed in Scilit:
- Posterior lumbar fusion by peek rods in degenerative spine: preliminary report on 30 casesEuropean Spine Journal, 2012
- Cost per quality-adjusted life year gained of laminectomy and extension of instrumented fusion for adjacent-segment disease: defining the value of surgical interventionJournal of Neurosurgery: Spine, 2012
- Biomechanical Assessment of a PEEK Rod System for Semi-Rigid Fixation of Lumbar Fusion ConstructsJournal of Biomechanical Engineering, 2011
- Adjacent segment degeneration after instrumented posterolateral lumbar fusion: a prospective cohort study with a minimum five-year follow-upEuropean Spine Journal, 2011
- The Mechanical Effect of Commercially Pure Titanium and Polyetheretherketone Rods on Spinal Implants at the Operative and Adjacent LevelsSpine, 2010
- Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixationThe Spine Journal, 2009
- Comparison of the load-sharing characteristics between pedicle-based dynamic and rigid rod devicesBiomedical Materials, 2008
- PEEK biomaterials in trauma, orthopedic, and spinal implantsBiomaterials, 2007
- Hybrid multidirectional test method to evaluate spinal adjacent-level effectsClinical Biomechanics, 2007