Cardiac Radiofrequency Ablation Simulation Using a 3D-Printed Bi-Atrial Thermochromic Model
Authors:
- Shu WangSWShu Wang
- Carlo SaijaCSCarlo Saija
- Justin ChooJCJustin Choo
- Zhanchong OuZOZhanchong Ou
- Maria BirsoanMBMaria Birsoan
- Sarah GermanosSGSarah Germanos
- Joshua RothwellJRJoshua Rothwell
- Behrad VakiliBVBehrad Vakili
- Irum KotadiaIKIrum Kotadia
- Zhouyang XuZXZhouyang Xu
- Adrian RoletARAdrian Rolet
- Adriana NamourANAdriana Namour
Open Access
- 28 June 2022
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 12 (13) , 6553
Abstract
Radiofrequency ablation (RFA) is a treatment used in the management of various arrhythmias including atrial fibrillation. Enhanced training for electrophysiologists through the use of physical simulators has a significant role in improving patient outcomes. The requirements for a high-fidelity simulator for cardiac RFA are challenging and not fully met by any research or commercial simulator at present. In this study, we have produced and evaluated a 3D-printed, bi-atrial model contained in a custom-made enclosure for RFA simulation using a new soft tissue-mimicking polymer, Layfomm-40, combined with thermochromic pigment and barium sulphate in an acrylic paint carrier. We evaluated the conductive properties of Layfomm-40, its sensitivity to RFA, and its visibility in X-ray imaging, and carried a full simulation of RFA in the cardiac catheterization laboratory by an electrophysiologist. We demonstrated that a patient-specific 3D-printed Layfomm-40 bi-atrial model coated with a custom thermochromic/barium sulphate paint was compatible with the CARTO3 electroanatomic mapping system and could be effectively imaged using X-ray fluoroscopy. We demonstrated the effective delivery and visualization of radiofrequency ablation lesions in this model. The simulator meets nearly all the requirements for high-fidelity physical simulation of RFA. The use of such simulators is likely to have impact on the training of electrophysiologists and the evaluation of novel RFA devices.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (WT 203148/Z/16/Z, (FS/20/26/34952))
- KCL-China Scholarship Scheme (WT 203148/Z/16/Z, (FS/20/26/34952))
- British Heat Foundation (WT 203148/Z/16/Z, (FS/20/26/34952))
This publication has 16 references indexed in Scilit:
- Development of simulation combining a physical heart model and three‐dimensional system for electrophysiology trainingPacing and Clinical Electrophysiology, 2018
- Synthesis and Irreversible Thermochromic Sensor Applications of Manganese VioletMaterials, 2018
- 3D printed bio-models for medical applicationsRapid Prototyping Journal, 2017
- Temperature sensitive colour-changed composites2017
- Thermochromic tissue-mimicking phantom for optimisation of thermal tumour ablationInternational Journal of Hyperthermia, 2016
- Better Lesion Creation And Assessment During Catheter Ablation.2015
- Reference right atrial dimensions and volume estimation by steady state free precession cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2013
- Simulator training reduces radiation exposure and improves trainees' performance in placing electrophysiologic catheters during patient-based proceduresHeart Rhythm, 2012
- Electrical Conductivity and Permittivity of Murine MyocardiumIEEE Transactions on Biomedical Engineering, 2009
- A polyacrylamide gel phantom for radiofrequency ablationInternational Journal of Hyperthermia, 2008