Metal-on-Metal Bearing: Is this the End of the Line? We Do Not Think So
Authors:
- 1 October 2012
- journal article
- review article
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 8 (3) , 262-269
Abstract
Background: Recent studies have recommended the discontinuation of metal-on-metal (MoM) components in total hip arthroplasty (THA) because of adverse effects reported with large-diameter MoM THA. This is despite favorable long-term results observed with 28 and 32 mm MoM bearings. Questions/purposes: The aim of this study was to assess the value of calls for an end to MoM bearings as THA components. Specifically, we wish to address the risks associated with MoM bearings including adverse soft tissue reactions, metal ion release, and carcinogenic risk. Methods: The study evaluates the arguments in the literature reporting on MoM (adverse soft tissue reactions, metal ion release, and carcinogenic risk) and the experience of the current authors who re-introduced these bearings in 1995. They are balanced by a benefit–risk review of the literature and the authors’ experience with MoM use. Results: Adverse reactions to metallic debris as well as metal ion release are predictable and can be prevented by adequate design (arc of coverage, clearance), metallurgy (forged instead of cast alloy, high-carbide content), and appropriate component orientation. There is no scientific evidence that carcinogenicity is increased in subjects with MoM hip prostheses. MoM articulations appear to be attractive allowing safe hip resurfacing, decreasing the risk of THA revision in active patients, and providing secure THA fixation with cement in cages in severely deformed hips. MoM bearings in women of child-bearing age are controversial, but long-term data on metallic devices in adolescents undergoing spinal surgery seem reassuring. Discussion: Adequate selection of MoM articulations ensures their safe use. These articulations are sensitive to orientation. Fifteen years of safe experience with 28- and 32-mm bearings of forged alloy and high-carbide content is the main reason for retaining them in primary and revision THA.Keywords
This publication has 98 references indexed in Scilit:
- Is Metal-on-Metal Squeaking Related to Acetabular Angle of Inclination?Clinical Orthopaedics and Related Research, 2011
- Early Reactive Synovitis and Osteolysis after Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2010
- Optimal bearing surfaces for total hip replacement in the young patient: a meta-analysisInternational Orthopaedics, 2010
- Hip resurfacing for rheumatoid arthritis: independent assessment of 11-year results from an international registerInternational Orthopaedics, 2010
- Two-year migration results of the ReCap hip resurfacing system—a radiostereometric follow-up study of 23 hipsInternational Orthopaedics, 2010
- The John Charnley Award: Metal-on-Metal Hip Resurfacing versus Large-diameter Head Metal-on-Metal Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2010
- 2008 John Charnley Award: Metal Ion Levels After Metal-on-Metal Total Hip Arthroplasty: A Randomized TrialClinical Orthopaedics and Related Research, 2009
- Surface Replacement is Comparable to Primary Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2009
- Resurfacing is Comparable to Total Hip Arthroplasty at Short-term FollowupClinical Orthopaedics and Related Research, 2009
- Metal levels in corrosion of spinal implantsEuropean Spine Journal, 2007