Postinfusion ReFacto AF levels can be difficult to measure accurately due to discrepancies between one-stage and chromogenic FVIII assays. To overcome this, the use of the ReFacto AF laboratory standard (RAFLS) is recommended, but there are discordant reports regarding its usefulness. We investigated whether calibration with RAFLS and measurement of ReFacto AF levels are influenced by the choice of reagents and patient-specific factors in one-stage FVIII assays. Calibration curves were generated with both the RAFLS and a plasma standard using different F8DPs and one-stage FVIII assay reagents. This selection of reagents was then used to determine FVIII levels in the plasma of patients repeatedly treated with ReFacto AF. Results were compared with those obtained with a chromogenic assay. F8DP devoid of von Willebrand factor (VWF) falsely increased the values of RAFLS pro-coagulant activity generated using the APTT reagent. The resulting RAFLS calibration curve underestimated ReFacto AF levels to be half of their true concentration. The use of RAFLS with F8DP containing VWF reduced the discrepancy observed between the one-stage and chromogenic FVIII assays. However, the mean difference between the two assays still varied up to 50% depending on the patient. The RAFLS is a suitable calibrator for one-stage FVIII assays carried out with F8DP containing VWF. However, calibration with the RAFLS does not avoid the effect of patient-specific variables that contribute to discrepancies between the measurements of ReFacto AF levels with one-stage and chromogenic FVIII assays.Keywords
Funding Information
- Pfizer
This publication has 15 references indexed in Scilit:
- Practical and cost‐effective measurement of B‐domain deleted and full‐length recombinant FVIII in the routine haemostasis laboratoryHaemophilia, 2013
- The use of the new ReFacto AF Laboratory Standard allows reliable measurement of FVIII:C levels in ReFacto AF mock plasma samples by a one‐stage clotting assayHaemophilia, 2011
- An improved manufacturing process for Xyntha/ReFacto AFHaemophilia, 2010
- Measurement of factor VIII activity using one‐stage clotting assay: a calibration curve has not to be systematically included in each runHaemophilia, 2010
- Performance of recalibrated ReFacto® laboratory standard in the measurement of FVIII plasma concentration via the chromogenic and one‐stage assays after infusion of recalibrated ReFacto® (B‐domain deleted recombinant factor VIII)Haemophilia, 2009
- Collaborative field study on the utility of a BDD factor VIII concentrate standard in the estimation of BDDr Factor VIII:C activity in hemophilic plasma using one-stage clotting assaysJournal of Thrombosis and Haemostasis, 2004
- A multicenter pharmacokinetic study of the B-domain deleted recombinant factor VIII concentrate using different assays and standardsJournal of Thrombosis and Haemostasis, 2003
- Influence of phospholipids on the assessment of factor VIII activityHaemophilia, 1998
- In vivo recovery with products of very high purity — assay discrepanciesHaemophilia, 1998
- Stabilization of Factor VIII in Plasma by the von Willebrand FactorJournal of Clinical Investigation, 1977