Continuous ventilation technique for laryngeal mask airway (LMATM) removal after fiberoptic intubation in children
Authors:
- 22 October 2004
- journal article
- Published by Wiley in Pediatric Anesthesia
- Vol. 14 (11) , 936-940
Abstract
Summary: Background : Fiberoptic tracheal intubation through the laryngeal mask airway (LMATM) is a simple technique to establish a safe airway in neonates and infants with a difficult airway. The technique, however, is complicated by the removal of the laryngeal mask from the patient's mouth because of the similarity in length of the LMA and the tracheal tube.Methods : Several solutions have been presented to stabilize the tracheal tube within the trachea during withdrawal of the LMA. With all these techniques ventilation of the patient is interrupted.Results : We present a modified technique, using a double tube assembly, which allows uninterrupted ventilation of the patient during withdrawal of the LMA from the patient's mouth.Conclusions : The technique is simple and safe, can be performed without hurry and carries potential advantages for neonates and children with limited cardiorespiratory reserve.Keywords
This publication has 29 references indexed in Scilit:
- Caution when using cuffed tracheal tubes for fibreoptic intubation through paediatric‐sized laryngeal mask airwaysActa Anaesthesiologica Scandinavica, 2004
- It???s a Disposable LMA, Just Cut It Shorter???for Fiberoptic IntubationAnesthesia & Analgesia, 2003
- Laryngeal mask airway longevity and pilot-balloon failureJournal of Clinical Anesthesia, 1997
- Blind Intubation through the Laryngeal Mask Airway for Management of the Difficult Airway in InfantsAnesthesiology, 1996
- Simple Technique to Remove Laryngeal Mask Airway "Guide" After Endotracheal IntubationAnesthesia & Analgesia, 1996
- Continuous Ventilation During Trans-Laryngeal Mask Airway Fiberoptic Bronchoscope-Aided Tracheal IntubationAnesthesia & Analgesia, 1996
- Fiberoptic Intubation via the Laryngeal Mask AirwayAnesthesia & Analgesia, 1994
- Heavy-ion resonance and statistical fission competition in theMg system at=44.4 MeVPhysical Review C, 1994
- Fiberoptic Intubation and the Laryngeal Mask AirwayAnesthesiology, 1993
- The distance between the grille of the laryngeal mask airway and the vocal cordsAnaesthesia, 1993