Can Transcranial Doppler Discriminate Between Solid and Gaseous Microemboli?
Authors:
- 1 August 2005
- journal article
- Published by Wolters Kluwer Health in Stroke
- Vol. 36 (8) , 1731-1734
Abstract
Background and Purpose— Transcranial Doppler ultrasound can reliably detect both gaseous and solid cerebral emboli. However, conventional equipment is unable to discriminate between gaseous and solid emboli. This is a major limitation in situations in which the 2 coexist, because they may have very different clinical relevance. Recently, a novel Embo-Dop system, using insonation at 2 ultrasound transducer frequencies, has been developed. An initial study with a small sample size suggested it provided excellent discrimination. We performed a validation study in subjects with embolic signals of known nature. Methods— Gaseous embolic signals were obtained in 7 patients with known patient foramen ovale by intravenous injection of agitated saline injections. Solid embolic signals were obtained in patients with symptomatic carotid stenosis (N=23). Discrimination of the 2 using the Embo-Dop system dual-frequency system was assessed. It was compared with discrimination using embolic signal maximum intensity with an intensity threshold. Results— One hundred forty-five solid embolic signals were recorded from carotid stenosis patients. Seventy-three were classified as solid and 72 as gaseous by the Embo-Dop system. Six hundred forty-eight gaseous embolic signals were recorded from 7 patients with patent foramen ovale. Six hundred twenty-five were classified as gaseous and 23 as solid. This gave a sensitivity of 50.3% and specificity of 96.5% for detecting solid embolic signals. Discrimination was better than using a simple intensity threshold. Conclusions— The Embo-Dop dual-frequency system allows better discrimination than a simple intensity threshold but it is not accurate enough for use in clinical or research studies. Further work is needed to develop reliable clinical systems for discrimination of emboli.Keywords
This publication has 19 references indexed in Scilit:
- Automatic Online Embolus Detection and Artifact Rejection With the First Multifrequency Transcranial DopplerStroke, 2002
- Online Automatic Discrimination Between Solid and Gaseous Cerebral Microemboli With the First Multifrequency Transcranial DopplerStroke, 2002
- Cessation of embolic signals after antithrombotic prevention is related to reduced risk of recurrent arterioembolic transient ischaemic attack and strokeJournal of Neurology, Neurosurgery & Psychiatry, 2002
- Doppler microembolic signals predict ischemic recurrences in symptomaticcarotid stenosisActa Neurologica Scandinavica, 2000
- The effects of temporal bone on transcranial Doppler ultrasound beam shapeUltrasound in Medicine & Biology, 2000
- Cerebral microembolism in patients with stroke or transient ischaemic attack as a risk factor for early recurrenceJournal of Neurology, Neurosurgery & Psychiatry, 1997
- Pulse Doppler ultrasound detection, characterization and size estimation of emboli in flowing bloodIEEE Transactions on Biomedical Engineering, 1994
- Microemboli and Cerebral Impairment During Cardiac SurgeryVascular Surgery, 1990
- The Detection of Microemboli in the Middle Cerebral Artery during Cardiopulmonary Bypass: A Transcranial Doppler Ultrasound Investigation Using Membrane and Bubble OxygenatorsThe Annals of Thoracic Surgery, 1987
- The Use of Ultrasonics in the Determination of Arterial Aeroembolism During Open-Heart SurgeryThe Annals of Thoracic Surgery, 1969