Technical considerations for genotyping multi-allelic copy number variation (CNV), in regions of segmental duplication
Open Access
- 1 May 2014
- journal article
- research article
- Published by Springer Nature in BMC Genomics
- Vol. 15 (1) , 1-8
Abstract
Intrachromosomal segmental duplications provide the substrate for non-allelic homologous recombination, facilitating extensive copy number variation in the human genome. Many multi-copy gene families are embedded within genomic regions with high levels of sequence identity (>95%) and therefore pose considerable analytical challenges. In some cases, the complexity involved in analyzing such regions is largely underestimated. Rapid, cost effective analysis of multi-copy gene regions have typically implemented quantitative approaches, however quantitative data are not an absolute means of certainty. Therefore any technique prone to degrees of measurement error can produce ambiguous results that may lead to spurious associations with complex disease. In this study we have focused on testing the accuracy and reproducibility of quantitative analysis techniques. With reference to the C-C Chemokine Ligand-3-like-1 (CCL3L1) gene, we performed analysis using real-time Quantitative PCR (QPCR), Multiplex Ligation-dependent Probe Amplification (MLPA) and Paralogue Ratio Test (PRT). After controlling for potential outside variables on assay performance, including DNA concentration, quality, preparation and storage conditions, we find that real-time QPCR produces data that does not cluster tightly around copy number integer values, with variation substantially greater than that of the MLPA or PRT systems. We find that the method of rounding real-time QPCR measurements can potentially lead to mis-scoring of copy number genotypes and suggest caution should be exercised in interpreting QPCR data. We conclude that real-time QPCR is inherently prone to measurement error, even under conditions that would seem favorable for association studies. Our results indicate that potential variability in the physicochemical properties of the DNA samples cannot solely explain the poor performance exhibited by the real-time QPCR systems. We recommend that more robust approaches such as PRT or MLPA should be used to genotype multi-allelic copy number variation in disease association studies and suggest several approaches which can be implemented to ensure the quality of the copy number typing using quantitative methods.Keywords
This publication has 31 references indexed in Scilit:
- Rapid and accurate large-scale genotyping of duplicated genes and discovery of interlocus gene conversionsNature Methods, 2013
- The Challenges of Studying Complex and Dynamic Regions of the Human Genome2011
- High-Throughput Droplet Digital PCR System for Absolute Quantitation of DNA Copy NumberAnalytical Chemistry, 2011
- Accuracy and differential bias in copy number measurement of CCL3L1 in association studies with three auto-immune disordersBMC Genomics, 2011
- Accurate and objective copy number profiling using real-time quantitative PCRMethods, 2010
- CCL3L1 and HIV/AIDS susceptibilityNature Medicine, 2009
- Experimental aspects of copy number variant assays at CCL3L1Nature Medicine, 2009
- CCL3L1 and HIV/AIDS susceptibilityNature Medicine, 2009
- A robust statistical method for case-control association testing with copy number variationNature Genetics, 2008
- A Chromosome 8 Gene-Cluster Polymorphism with Low Human Beta-Defensin 2 Gene Copy Number Predisposes to Crohn Disease of the ColonThe American Journal of Human Genetics, 2006