Optimization of single injection liver arterial phase gadolinium enhanced MRI using bolus track real‐time imaging
Authors:
- 22 December 2010
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 33 (1) , 110-118
Abstract
Purpose: To measure contrast agent enhancement kinetics in the liver and to further evaluate and develop an optimized gadolinium enhanced MRI using a single injection real‐time bolus‐tracking method for reproducible imaging of the transient arterial‐phase. Materials and Methods: A total of 18 subjects with hypervascular liver lesions were imaged with four dimensional (4D) perfusion scans to measure time‐to‐peak (TTP) delays of arterial (aorta‐celiac axis), liver parenchyma, liver lesion, portal, and hepatic veins. Time delays were calculated from the TTP‐aorta signal, and then related to the gradient echo (GRE) k‐space acquisition design, to determine optimized timing for real‐time bolus‐track triggering methodology. As another measure of significance, 200 clinical patients were imaged with 3D‐GRE using either a fixed time‐interval or by individualized arterial bolus real‐time triggering. Bolus TTP‐aorta was calculated and arterial‐phase acquisitions were compared for accuracy and reproducibility using specific vascular enhancement indicators. Results: The mean bolus transit‐time to peak‐lesion contrast was 8.1 ± 2.7 seconds following arterial detection, compared to 32.1 ± 5.4 seconds from contrast injection, representing a 62.1% reduction in the time‐variability among subjects (N = 18). The real‐time bolus‐triggered technique more consistently captured the targeted arterial phase (94%), compared to the fixed timing technique (73%), representing an expected improvement of timing accuracy in 28% of patients (P = 0.0001389). Conclusion: Our results show detailed timing window analysis required for optimized arterial real‐time bolus‐triggering acquisition of transient arterial phase features of liver lesions, with optimized arterial triggering expected to improve reproducibility in a significant number of patients. J. Magn. Reson. Imaging 2011;33:110–118.Keywords
This publication has 16 references indexed in Scilit:
- Timing bolus dynamic contrast‐enhanced (DCE) MRI assessment of hepatic perfusion: Initial experienceJournal of Magnetic Resonance Imaging, 2009
- Evaluation of optimized inversion‐recovery fat‐suppression techniques for T2‐weighted abdominal MR imagingJournal of Magnetic Resonance Imaging, 2008
- Reversible heterogeneous arterial phase liver perfusion associated with transient acute hepatitis: Findings on gadolinium‐enhanced MRIJournal of Magnetic Resonance Imaging, 2004
- From the RSNA Refresher CoursesRadioGraphics, 2003
- Hepatic Arterial Phase MR Imaging with Automated Bolus-Detection Three-dimensional Fast Gradient-Recalled-Echo Sequence: Comparison with Test-Bolus MethodRadiology, 2003
- Gadolinium-enhanced MR Imaging of the Liver: Optimizing Imaging Delay for Hepatic Arterial and Portal Venous Phases—A Prospective Randomized Study in Patients with Chronic Liver DamageRadiology, 2002
- Abdominal MR Imaging with a Volumetric Interpolated Breath-hold ExaminationRadiology, 1999
- Hepatic enhancement analysis in children using Smart Prep monitoring for 2 : 1 pitch helical scanningPediatric Radiology, 1999
- Transient increased segmental hepatic enhancement distal to portal vein obstruction on dynamic gadolinium‐enhanced gradient echo MR imagesJournal of Magnetic Resonance Imaging, 1995
- Magnetic Resonance Imaging of the LiverTopics in Magnetic Resonance Imaging, 1995