Detection and Isolation of DoS and Integrity Cyber Attacks in Cyber-Physical Systems with a Neural Network-Based Architecture
Open Access
- 12 September 2021
- journal article
- research article
- Published by MDPI AG in Electronics
- Vol. 10 (18) , 2238
Abstract
New applications of industrial automation request great flexibility in the systems, supported by the increase in the interconnection between its components, allowing access to all the information of the system and its reconfiguration based on the changes that occur during its operations, with the purpose of reaching optimum points of operation. These aspects promote the Smart Factory paradigm, integrating physical and digital systems to create smarts products and processes capable of transforming conventional value chains, forming the Cyber-Physical Systems (CPSs). This flexibility opens a large gap that affects the security of control systems since the new communication links can be used by people to generate attacks that produce risk in these applications. This is a recent problem in the control systems, which originally were centralized and later were implemented as interconnected systems through isolated networks. To protect these systems, strategies that have presented acceptable results in other environments, such as office environments, have been chosen. However, the characteristics of these applications are not the same, and the results achieved are not as expected. This problem has motivated several efforts in order to contribute from different approaches to increase the security of control systems. Based on the above, this work proposes an architecture based on artificial neural networks for detection and isolation of cyber attacks Denial of Service (DoS) and integrity in CPS. Simulation results of two test benches, the Secure Water Treatment (SWaT) dataset, and a tanks system, show the effectiveness of the proposal. Regarding the SWaT dataset, the scores obtained from the recall and F1 score metrics was and was higher than other reported works, while, in terms of precision and accuracy, it obtained a score of which is close to other proposed methods. With respect to the interconnected tank system, scores of , and were obtained for the accuracy, precision, F1 score, and recall metrics, respectively. The high true negatives rate in both cases is noteworthy. In general terms, the proposal has a high effectiveness in detecting and locating the proposed attacks.
Keywords
This publication has 71 references indexed in Scilit:
- Multi-fault Diagnosis in Three Coupled Tank System using Unknown Input ObserverIFAC-PapersOnLine, 2016
- Characterization of Cyberattacks Aimed at Integrated Industrial Control and Enterprise Systems: A Case Study2016
- Security, privacy and trust in Internet of Things: The road aheadComputer Networks, 2015
- A survey of intrusion detection techniques for cyber-physical systemsACM Computing Surveys, 2014
- Attack Detection and Identification in Cyber-Physical SystemsIEEE Transactions on Automatic Control, 2013
- Security for control systems under sensor and actuator attacks2012
- SCADA security in the light of Cyber-WarfareComputers & Security, 2012
- Communication security in SCADA pipeline monitoring systems2011
- Inside the Slammer wormIEEE Security & Privacy, 2003
- Robust Regression & Outlier DetectionJournal of Educational Statistics, 1988