The second generation cryoballoon has improved durable isolation of left but not right pulmonary veins: new insights from a multicentre study
- 1 July 2017
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (7) , 1115-1121
Abstract
Pulmonary vein isolation (PVI) using second-generation cryoballoon (CB2) is associated with improved outcomes compared with first generation (CB1). We aimed at investigating the characteristics of left and right PV reconnections after CB1 and CB2 ablations in patients with clinical recurrences requiring redo ablation. From 2010 to 2016, 776 patients underwent 28-mm cryoballoon PVI for symptomatic paroxysmal atrial fibrillation (AF) in 3 centres, 279 with CB1 and 497 with CB2. Among them, 94 patients (12.1%) had symptomatic AF recurrences requiring a redo ablation [43 (15.4%) CB1 and 51 (10.3%) CB2]. The benefit of CB2 over CB1 was compared for each PV. Durable PVI was confirmed in 7 CB1 (16.3%) and 14 CB2 (27.4%) patients, and 2.7 ± 2.1 and 1.4 ± 1.4 gaps per patient were found, respectively (P = 0.002). Significantly more left superior and left inferior PVs were found to be isolated in CB2 compared with CB1 group (78.4% vs. 48.8%, P = 0.005 and 78.4% vs. 46.5%, P = 0.003, respectively) while the rate of durable right superior and right inferior PVs isolation were similar (68.6% vs. 60.5%, P = 0.542 and 66.7% vs. 55.8%, P = 0.387, respectively). Significantly fewer gaps were found in left PVs in CB2 patients, while there was no significant difference for right PVs. Gaps localization was similar in both groups. Fewer reconnection gaps are observed during redo ablations of paroxysmal AF in patients primarily ablated with CB2. This difference is driven by less reconnection gaps observed in both left PVs, while no difference was observed for right PVs.Keywords
This publication has 20 references indexed in Scilit:
- Clinical recurrence and electrical pulmonary vein reconnections after second-generation cryoballoon ablationHeart Rhythm, 2016
- Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial FibrillationThe New England journal of medicine, 2016
- Characterization of Electrical Reconnection Following Pulmonary Vein Isolation Using First‐ and Second‐Generation CryoballoonPacing and Clinical Electrophysiology, 2016
- Safety and efficacy of second-generation versus first-generation cryoballoons for treatment of atrial fibrillation: a meta-analysis of current evidenceJournal of Interventional Cardiac Electrophysiology, 2015
- Once Isolated, Always Isolated?Circulation: Arrhythmia and Electrophysiology, 2015
- Durability of Pulmonary Vein Isolation with Cryoballoon Ablation: Results from the Sustained PV Isolation with Arctic Front Advance (SUPIR) StudyJournal of Cardiovascular Electrophysiology, 2015
- High rate of durable pulmonary vein isolation after second-generation cryoballoon ablation: analysis of repeat proceduresEP Europace, 2015
- Safety and efficacy of a second-generation cryoballoon in the ablation of paroxysmal atrial fibrillationHeart Rhythm, 2014
- Characterization of conduction recovery after pulmonary vein isolation using the “single big cryoballoon” techniqueHeart Rhythm, 2010
- Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary VeinsThe New England journal of medicine, 1998