Results of laser in situ keratomileusis performed using solid-state laser technology
Authors:
- David P. PiñeroDavid P. Piñero
- Rafael J. Pérez-CambrodíRPRafael J. Pérez-Cambrodí
- Aránzazu Gómez-HurtadoAGAránzazu Gómez-Hurtado
- Francisco J. Blanes-MompóFBFrancisco J. Blanes-Mompó
- Antonio Alzamora-RodríguezAAAntonio Alzamora-Rodríguez
- 1 March 2012
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (3) , 437-444
Abstract
E series. METHODS: This study evaluated consecutive eyes with low to moderate myopia that had LASIK performed using a Pulzar Z1 solid-state laser. Visual, refractive, and aberrometry changes as well as potential complications were evaluated. RESULTS: The study enrolled 60 eyes (34 patients). The mean follow-up was 8.5 months (range 6 to 13 months). There was a significant improvement in logMAR uncorrected distance visual acuity (UDVA) postoperatively (P<.01). No significant change was detected in logMAR corrected distance visual acuity (CDVA) (P=.21). The postoperative logMAR UDVA was 0.1 (approximately 20/25) or better in 57 eyes (95.00%). The mean overall efficacy index was 0.99 and the mean safety index, 1.02. Postoperatively, 1 eye (1.67%) lost lines (1 line) of CDVA. The postoperative spherical equivalent was within ±0.50 diopter in 58 eyes (96.67%). There was a small, but statistically significant increase in the primary coma root mean square (0.17 μm) and in the magnitude of primary spherical aberration (0.09 μm). No severe complications occurred. CONCLUSION: Laser in situ keratomileusis using the solid-state laser provided predictable correction of low to moderate myopia, minimizing the induction of higher-order aberrations and preserving CDVA. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned....Keywords
This publication has 18 references indexed in Scilit:
- LASIK for Myopia and Astigmatism Using the SCHWIND AMARIS Excimer Laser: An International Multicenter TrialJournal of Refractive Surgery, 2010
- LASIK for Myopia With Aspheric “Aberration Neutral” Ablations Using the ESIRIS Laser SystemJournal of Refractive Surgery, 2009
- Simultaneous Topography-guided PRK Followed by Corneal Collagen Cross-Linking for KeratoconusJournal of Refractive Surgery, 2009
- Advances in technologies for laser-assistedin situkeratomileusis (LASIK) surgeryExpert Review of Medical Devices, 2008
- Endothelial cell density after photorefractive keratectomy for moderate myopia using a 213 nm solid-state laser systemJournal of Cataract & Refractive Surgery, 2007
- One-year results of photorefractive keratectomy and laser in situ keratomileusis for myopia using a 213 nm wavelength solid-state laserJournal of Cataract & Refractive Surgery, 2007
- Histological Changes and Unscheduled DNA Synthesis in the Rabbit Cornea Following 213-nm, 193-nm, and 266-nm IrradiationJournal of Refractive Surgery, 2007
- Laser eye surgery for refractive errorsThe Lancet, 2006
- Power vector analysis of the optical outcome of refractive surgeryJournal of Cataract & Refractive Surgery, 2001