Intrastromal corneal ring segment implantation for high astigmatism after penetrating keratoplasty
Authors:
- Pedro Arriola-VillalobosPAPedro Arriola-Villalobos
- David Díaz-ValleDDDavid Díaz-Valle
- Jose Luis GüellJGJose Luis Güell
- María Teresa Iradier-UrrutiaMIMaría Teresa Iradier-Urrutia
- Iñigo Jiménez-AlfaroIJIñigo Jiménez-Alfaro
- Ricardo Cuiña-SardiñaRCRicardo Cuiña-Sardiña
- José Manuel Benítez-Del-CastilloJBJosé Manuel Benítez-Del-Castillo
- 1 November 2009
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 35 (11) , 1878-1884
Abstract
To evaluate the safety and efficacy of intracorneal ring segments (ICRS) for high astigmatism after penetrating keratoplasty (PKP). Department of Ocular Surface and Inflammation, Ophthalmology, Hospital Clínico San Carlos, Complutense University, Madrid, Spain. This retrospective noncomparative study comprised eyes with high post-PKP astigmatism (>4.00 diopters [D]), contact lens intolerance, and a minimum follow-up of 24 months who had ICRS (Kerarings) implantation by mechanical stromal dissection. Corrected distance visual acuity (CDVA), refractive astigmatism, spherical equivalent (SE), surgically induced astigmatism (SIA), central corneal curvature, topographic corneal astigmatism, average corneal power, and complications were assessed. The mean CDVA was statistically significantly better postoperatively (0.23 +/- 0.21) than preoperatively (0.98 +/- 0.27) (P = .007); no eye lost CDVA. The mean refractive astigmatism decreased from 6.17 +/- 1.12 D to 4.04 +/- 1.67 D (P = .068) and the mean SE from -3.17 +/- 5.48 D to -0.12 +/- 2.40 D (P = .34). The mean SIA was 4.55 +/- 2.83 D. The mean central corneal curvature decreased from 46.28 +/- 1.73 D to 42.09 +/- 3.20 D (P<.01); the mean topographic corneal astigmatism, from 7.07 +/- 2.52 D to 4.48 +/- 2.00 D (P<.05) and the mean average corneal power from 45.92 +/- 1.59 D to 41.88 +/- 3.37 D (P<.01); all decreases were statistically significant. One patient developed deep vascularization in the lower temporal stromal channel that resolved after ICRS removal. One patient reported significant night halos. Implantation of ICRS for high post-PKP astigmatism reduced corneal curvature and topographic astigmatism, significantly improving CDVA.Keywords
This publication has 28 references indexed in Scilit:
- Refractive surgery after corneal transplantationCurrent Opinion in Ophthalmology, 2005
- Standardized arcuate keratotomy for postkeratoplasty astigmatismJournal of Cataract & Refractive Surgery, 2005
- Laser in situ keratomileusis after penetrating keratoplastyJournal of Cataract & Refractive Surgery, 2001
- Laser in situ keratomileusis to correctrefractive errors after keratoplastyJournal of Cataract & Refractive Surgery, 1999
- Paradoxical response to photorefractive treatment for postkeratoplasty astigmatismJournal of Cataract & Refractive Surgery, 1998
- Corneal Scarring After Photorefractive Keratectomy in a Penetrating KeratoplastyAmerican Journal of Ophthalmology, 1996
- Excmier Laser Keratectomy for Astigmatism Occurring after Penetrating KeratoplastyOphthalmology, 1996
- Progression of Visual Acuity after Penetrating KeratoplastyOphthalmology, 1991
- Surgical Advances and Results of KeratoconusAmerican Journal of Ophthalmology, 1980