Evaluation of Near-Infrared Reflectance and Transflectance Sensing System for Predicting Manure Nutrients
Open Access
- 16 February 2022
- journal article
- research article
- Published by MDPI AG in Remote Sensing
- Vol. 14 (4) , 963
Abstract
Livestock manure is widely applied onto agriculture soil to fertilize crops and increase soil fertility. However, it is difficult to provide real-time manure nutrient data based on traditional lab analyses during application. Manure sensing using near-infrared (NIR) spectroscopy is an innovative, rapid, and cost-effective technique for inline analysis of animal manure. This study investigated a NIR sensing system with reflectance and transflectance modes to predict N speciation in dairy cow manure using a spiking method. In this study, 20 dairy cow manure samples were collected and spiked to achieve four levels of ammoniacal nitrogen (NH4-N) and organic nitrogen (Org-N) concentrations that resulted in 100 samples in each spiking group. All samples were scanned and analyzed using a NIR system with reflectance and transflectance sensor configurations. NIR calibration models were developed using partial least square regression analysis for NH4-N, Org-N, total solid (TS), ash, and particle size (PS). Coefficient of determination (R2) and root mean square error (RMSE) were selected to evaluate the models. A transflectance probe with a 1 mm path length had the best performance for analyzing manure constituents among three path lengths. Reflectance mode improved the calibration accuracy for NH4-N and Org-N, whereas transflectance mode improved the model predictability for TS, ash, and PS. Reflectance provided good prediction for NH4-N (R2 = 0.83; RMSE = 0.65 mg mL−1) and approximate predictions for Org-N (R2 = 0.66; RMSE = 1.18 mg mL−1). Transflectance was excellent for TS predictions (R2 = 0.97), and provided good quantitative predictions for ash and approximate predictions for PS. The correlations between the accuracy of NH4-N and Org-N calibration models and other manure parameters were not observed indicating the predictions of N contents were not affected by TS, ash, and PS.Keywords
Funding Information
- Dairy Innovation Hub (N/A)
This publication has 31 references indexed in Scilit:
- NIR Monitoring of Ammonia in Anaerobic Digesters Using a Diffuse Reflectance ProbeSensors, 2012
- Near‐infrared spectroscopy for within‐field soil characterization: small local calibrations compared with national libraries spiked with local samplesEuropean Journal of Soil Science, 2010
- Spiking of NIR regional models using samples from target sites: Effect of model size on prediction accuracyGeoderma, 2010
- Evaluating near infrared spectroscopy for field prediction of soil propertiesSoil Research, 2009
- Comparing local vs. global visible and near-infrared (VisNIR) diffuse reflectance spectroscopy (DRS) calibrations for the prediction of soil clay, organic C and inorganic CGeoderma, 2008
- Rapid Estimation of the Composition of Animal Manure Compost by near Infrared Reflectance SpectroscopyJournal of Near Infrared Spectroscopy, 2007
- Comparison of Transflectance and Reflectance to Analyse Hog ManuresJournal of Near Infrared Spectroscopy, 2005
- Potential for On-Site Analysis of Hog Manure Using a Visual and near Infrared Diode Array Reflectance SpectrometerJournal of Near Infrared Spectroscopy, 2004
- Rapid Analysis of Hog Manure and Manure‐amended Soils Using Near‐infrared SpectroscopySoil Science Society of America Journal, 2002
- Manure Sampling for Nutrient Analysis: Variability and Sampling EfficacyJournal of Environmental Quality, 2001