B0 mapping with multi‐channel RF coils at high field
Open Access
- 23 May 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (4) , 976-988
Abstract
Mapping the static magnetic field via the phase evolution over gradient echo scans acquired at two or more echo times is an established method. A number of possibilities exist, however, for combining phase data from multi‐channel coils, denoising and thresholding field maps for high field applications. Three methods for combining phase images when no body/volume coil is available are tested: (i) Hermitian product, (ii) phase‐matching over channels, and (iii) a new approach based on calculating separate field maps for each channel. The separate channel method is shown to yield field maps with higher signal‐to‐noise ratio than the Hermitian product and phase‐matching methods and fewer unwrapping errors at low signal‐to‐noise ratio. Separate channel combination also allows unreliable voxels to be identified via the standard deviation over channels, which is found to be the most effective means of denoising field maps. Tests were performed using multichannel coils with between 8 and 32 channels at 3 T, 4 T, and 7 T. For application in the correction of distortions in echo‐planar images, a formulation is proposed for reducing the local gradient of field maps to eliminate signal pile‐up or swapping artifacts. Field maps calculated using these techniques, implemented in a freely available MATLAB toolbox, provide the basis for an effective correction for echo‐planar imaging distortions at high fields. Magn Reson Med, 2011.Keywords
This publication has 32 references indexed in Scilit:
- An optimised framework for reconstructing and processing MR phase imagesNeuroImage, 2010
- 96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluationMagnetic Resonance in Medicine, 2009
- Rapid single‐scan T‐mapping using exponential excitation pulses and image‐based correction for linear background gradientsMagnetic Resonance in Medicine, 2009
- Phase unwrapping of MR images using ΦUN – A fast and robust region growing algorithmMedical Image Analysis, 2009
- Development of a robust method for generating 7.0 T multichannel phase images of the brain with application to normal volunteers and patients with neurological diseasesNeuroImage, 2008
- MR venography of the human brain using susceptibility weighted imaging at very high field strengthMagnetic Resonance Materials in Physics, Biology and Medicine, 2008
- High-field MRI of brain cortical substructure based on signal phaseProceedings of the National Academy of Sciences of the United States of America, 2007
- Comparison of fMRI activation as measured with gradient- and spin-echo EPI during visual perceptionNeuroImage, 2005
- Image distortion correction in EPI: Comparison of field mapping with point spread function mappingMagnetic Resonance in Medicine, 2002
- Image Distortion Correction in fMRI: A Quantitative EvaluationNeuroImage, 2002