In-Vitro Assessment of the Effects of Transcatheter Aortic Valve Leaflet Design on Neo-Sinus Geometry and Flow
Authors:
- 23 October 2020
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (3) , 1046-1057
Abstract
Transcatheter aortic valve (TAV) leaflet thrombosis is a clinical risk with potentially fatal consequences. Studies have identified neo-sinus flow stasis as a cause of leaflet thrombosis. Flow stasis is influenced by the TAV leaflets, which affect the local fluid dynamics in the aortic sinus and neo-sinus. This study evaluated the effects of TAV leaflet features on the neo-sinus flow as a measure of leaflet thrombosis risk. Five TAVs of varied leaflet length and insertion height were tested in a simulator. Hydrodynamics and leaflet kinematics through en-phase imaging were quantified. Velocity fields were assessed using high-speed particle image velocimetry. Regions of flow stasis and particle residence times (PRTs) were quantified. TAVs with shorter leaflet length exhibited larger orifice areas and lower transvalvular pressure gradients. Shorter leaflet length and increased leaflet insertion TAVs additionally exhibited lower neo-sinus PRTs (0.44 ± 0.21 vs 2.83 ± 0.48 cycles, p < 0.05) and higher neo-sinus peak velocities (0.15 ± 0.009 vs 0.07 ± 0.005 m/s, p < 0.05) than TAVs with longer leaflet length and lower leaflet insertion. The average neo-sinus volume positively correlated with PRT(r = 0.810, p < 0.001), and extent of flow stasis (r = 0.682, p < 0.05). These results suggest that a small neo-sinus volume may reduce flow stagnation and particle residence, potentially reducing the risk of leaflet thrombosis. We propose that leaflet design features might be proactively controlled in the design of future transcatheter aortic valves.Keywords
Funding Information
- Tom & Shirley Gurley
- Mary and James Wesley Fellowship Endowment
This publication has 29 references indexed in Scilit:
- Valve Type, Size, and Deployment Location Affect Hemodynamics in an In Vitro Valve-in-Valve ModelJACC: Cardiovascular Interventions, 2016
- The Effect of Valve-in-Valve Implantation Height on Sinus FlowAnnals of Biomedical Engineering, 2016
- How Can We Help a Patient With a Small Failing Bioprosthesis?JACC: Cardiovascular Interventions, 2015
- Early hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valvesEuropean Heart Journal, 2015
- Thrombus Formation Following Transcatheter Aortic Valve ReplacementJACC: Cardiovascular Interventions, 2015
- Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo SurgeryCurrent Cardiology Reports, 2011
- Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo SurgeryThe New England journal of medicine, 2010
- Ex vivo and in vivo coronary ostial locations in humansSurgical and Radiologic Anatomy, 2009
- Fluid Mechanics of Heart ValvesAnnual Review of Biomedical Engineering, 2004
- The geometry of the aortic root in health, at valve disease and after valve replacementJournal of Biomechanics, 1990