Dynamic Modelling of Data Center Waste Heat Potential Integration in District Heating in Latvia
Open Access
Abstract
As demand for data centers (DC) has increased rapidly, so has their electricity consumption. Cooling DCs is essential to maintain optimal temperatures for the operation of servers and equipment. The consequence of the cooling process is that most of the electricity consumed in DCs, including cooling, is eventually dissipated as heat that is released into the atmosphere without any useful application. Recovering and reusing waste heat offers a sustainable solution to reduce primary energy consumption and minimize the environmental impact. Using waste heat from DCs to heat buildings can significantly improve the energy efficiency and environmental sustainability of DCs. Therefore, this research analyzes the existing potential of waste heat recovery from data centers in Latvia and proposes a system dynamic modelling approach for evaluation of the future impact of waste heat on the national heat supply. The overall waste heat generated by DCs in 2022 was 51.37 GWh at a temperature of 65 °C. By 2050, the total heat energy production potential from DCs will increase to 257 GWh, with 201 GWh being utilized.Keywords
Funding Information
- Nordic Energy Research (117686)
This publication has 25 references indexed in Scilit:
- A decision support system for waste heat recovery and energy efficiency improvement in data centresApplied Energy, 2019
- Thermoeconomic and environmental feasibility of waste heat recovery of a data center using air source heat pumpJournal of Cleaner Production, 2019
- Waste heat recovery from urban air cooled data centres to increase energy efficiency of district heating networksSustainable Cities and Society, 2019
- Analysis of a district heating system using waste heat in a distributed cooling data centerApplied Thermal Engineering, 2018
- A simplified power consumption model of information technology (IT) equipment in data centers for energy system real-time dynamic simulationApplied Energy, 2018
- Future views on waste heat utilization – Case of data centers in Northern EuropeRenewable and Sustainable Energy Reviews, 2018
- Design and economic analysis of liquid cooled data centres for waste heat recovery: A case study for an indoor swimming poolSustainable Cities and Society, 2018
- Levelized cost of energy calculations for microgrids2016
- Development of an energy evaluation and design tool for dedicated cooling systems of data centers: Sensing data center cooling energy efficiencyEnergy and Buildings, 2015
- Data Centers—Strategic Planning, Design, Construction, and Operations2014