Use of Three‐Dimensional Catheter Guidance and Trans‐Esophageal Echocardiography to Eliminate Fluoroscopy in Catheter Ablation of Left‐Sided Accessory Pathways
Authors:
- 28 February 2008
- journal article
- clinical trial
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 31 (3) , 283-289
Abstract
Background: Newer technologies such as three‐dimensional mapping and echocardiography can decrease x‐ray exposure during catheter ablation. Many right‐sided tachycardias can now be ablated without fluoroscopy. Left‐sided tachycardias, however, have not yet been ablated using a zero fluoroscopy approach. Objective: This study sought to examine the utility of trans‐esophageal echocardiography (TEE) in providing adequate imaging as an alternative to fluoroscopy for transseptal puncture. When combined with NavX guidance (St. Jude Medical, St. Paul, MN, USA), fluoroscopy may not be necessary. Methods: Ten pediatric patients with supraventricular tachycardia (SVT) had accessory pathways mapped to the left side. Right atrial and coronary sinus geometries were created using NavX. Once a left‐sided pathway was confirmed, a transseptal puncture was performed. A guide wire was placed in the SVC and confirmed by TEE. A transseptal sheath and dilator were advanced over the wire and positioned with TEE guidance so that the tip of the dilator was tenting the fossa ovalis. A transseptal needle was advanced across the fossa. Left atrial location of the needle tip was confirmed on TEE by saline contrast injection. The sheath and dilator were advanced over the needle with continuous pressure monitoring and TEE. Once the sheath was appropriately positioned, the ablation was completed using NavX guidance. Results: All patients had acutely successful ablations and none required the use of fluoroscopy. Number of cryo lesions ranged from five to 19, with a mean of 9. Mean procedure time was 4.4 hours, with a range of 3.2 hours to 7.2 hours. There were no complications. One patient had recurrence. Conclusions: Three‐dimensional mapping combined with TEE shows potential for eliminating fluoroscopy use during catheter ablation.Keywords
This publication has 20 references indexed in Scilit:
- Nonfluoroscopic Catheter Navigation for Radiofrequency Catheter Ablation of Supraventricular Tachycardia in ChildrenPacing and Clinical Electrophysiology, 2006
- Characterization of Conduction Recovery Across Left Atrial Linear Lesions in Patients with Paroxysmal and Persistent Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2006
- P1-49Heart Rhythm, 2006
- X-Ray Dose Reduction in Fluoroscopically Guided Electrophysiology ProceduresPacing and Clinical Electrophysiology, 2006
- Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system†European Heart Journal, 2005
- Transseptal catheterizationHeart Rhythm, 2005
- Catheter Ablation of Common‐Type Atrial Flutter Guided by Three‐Dimensional Right Atrial Geometry Reconstruction and Catheter Tracking Using Cutaneous Patches:Journal of Cardiovascular Electrophysiology, 2004
- Application of low dose rate pulsed fluoroscopy in cardiac pacing and electrophysiology: patient dose and image quality implicationsBritish Journal of Radiology, 2004
- Exclusion of Fluoroscopy During Ablation Treatment of Right Accessory Pathway in ChildrenJournal of Cardiovascular Electrophysiology, 2002
- Radiation exposure to patients and medical personnel during radiofrequency catheter ablation for supraventricular tachycardiaThe American Journal of Cardiology, 1992