A New Cr3+ Electrochemical Sensor Based on ATNA/Nafion/Glassy Carbon Electrode
Open Access
Abstract
A new electrochemical sensor of metal cation in an aqueous solution based on homobifunctional tridentate disulfide Schiff base and named 1,1′-(-((disulfanediylbis(2,1-phenylene))bis(azaneylylidene))bis(methaneylylidene))bis(naphthalene-2-ol) (ATNA) was easily obtained quantitatively from the condensation reaction of 2-hydroxy-1-naphthaldehyde and 2-aminothiophenol, and then fully characterized by spectroscopic techniques for structure elucidation. The molecular structure of ATNA was also confirmed by a single-crystal X-ray diffraction study to reveal a new conformation in which the molecule was stabilized by the O–H…N type intramolecular hydrogen bonding interactions in both moieties. The ATNA was used as a selective electrochemical sensor for the detection of chromium ion (Cr3+). A thin film of ATNA was coated on to the flat surface of glassy carbon electrode (GCE) followed by 5 % ethanolic Nafion in order to make the modified GCE (ATNA/Nafion/GCE) as an efficient and sensitive electrochemical sensor. It was found to be very effective and selective against Cr3+ cations in the company of other intrusive heavy metal cations such as Al3+, Ce3+, Co2+, Cu2+, Ga3+, Hg2+, Mn2+, Pb2+, and Y3+. The detection limit at 3 S/N was found to be 0.013 nM for Cr3+ ions within the linear dynamic range (LDR) (0.1 nM–10.0 mM) of Cr3+ ions with r2 = 0.9579. Moreover; this work instigates a new methodology for developing the sensitive as well as selective electrochemical toxic cationic sensors in the field of environmental and health care.Keywords
Funding Information
- King Abdulaziz University (DF-671-130-1441)
This publication has 60 references indexed in Scilit:
- Physiochemical interactions of chiral Schiff bases on high carbon steel surface: Corrosion inhibition in acidic mediaProgress in Organic Coatings, 2013
- Using ion-pair reversed-phase HPLC ICP-MS to simultaneously determine Cr(III) and Cr(VI) in urine of chromate workersTalanta, 2010
- Exploring surface chemistry of nano-TiO2 for automated speciation analysis of Cr(iii) and Cr(vi) in drinking water using flow injection and ET-AAS detectionJournal of Analytical Atomic Spectrometry, 2009
- A short history of SHELXActa Crystallographica Section A Foundations of Crystallography, 2007
- Chromium(III) selective membrane sensors based on Schiff bases as chelating ionophoresAnalytica Chimica Acta, 2007
- Optimisation procedure for the inhibitive determination of chromium(III) using an amperometric tyrosinase biosensorAnalytica Chimica Acta, 2004
- Separation of picogram quantities of Cr(iii) and Cr(vi) species in aqueous solutions and determination by graphite furnace atomic absorption spectrometryJournal of Analytical Atomic Spectrometry, 2002
- WinGXsuite for small-molecule single-crystal crystallographyJournal of Applied Crystallography, 1999
- Speciation of chromium by solid-phase extraction coupled to reversed-phase liquid chromatography with UV detectionAnalytica Chimica Acta, 1998
- Simultaneous Determination of Chromium(VI) and Chromium(III) by Capillary ElectrophoresisAnalytical Sciences, 1998