Variability of Mechanical Torque‐Limiting Devices in Clinical Service at a US Dental School
- 6 January 2010
- journal article
- research article
- Published by Wiley in Journal of Prosthodontics
- Vol. 19 (1) , 20-24
Abstract
Purpose: The purpose of this study was to measure the variability of torque produced by a population of mechanical torque‐limiting devices in clinical service in a US dental school. The torque‐limiting devices were divided into two categories according to their mode of action: toggle‐type and beam wrenches. Proper action of these devices is essential for calibrated delivery of preload to implant prosthetic screws. Materials and Methods: Seventeen torque‐limiting devices (35 Ncm) were obtained from graduate prosthodontic, predoctoral, and faculty practice clinics. Nine of these were toggle‐type devices, and eight were beam‐type wrenches. Torque from each wrench was measured using an MGT electronic torque meter. Wrenches were tested in two modes, slow (over 4 seconds) and fast (over 1 second). Results: Toggle‐type torque wrenches produced a mean (± SD) torque of 38.1 ± 16.0 Ncm; beam‐type wrenches produced 32.8 ± 1.1 Ncm. These results were not significantly different. When tested in fast mode (1 second), toggle‐type wrenches produced 28.0 ± 9.6 Ncm; in the slow mode (4 seconds) they produced significantly more force, 36.6 ± 14.0 Ncm (p < 0.001). Beam‐type wrenches produced 33.2 ± 1.1 Ncm and 32.8 ± 1.1 Ncm in fast and slow modes, respectively. Conclusions: Both types of wrenches tested were capable of producing accurate torque values; however, variability was higher in the toggle‐type group. Some toggle‐type torque wrenches in clinical service delivered unacceptably high torque values. It is recommended that clinicians calibrate toggle‐type wrenches frequently. Torque wrenches should be activated slowly, over 4 seconds, when using a correctly calibrated toggle‐type wrench.Keywords
This publication has 10 references indexed in Scilit:
- Accuracy of friction-style and spring-style mechanical torque limiting devices for dental implantsThe Journal of Prosthetic Dentistry, 2008
- Implant Abutment Screw Torque Generated by General Dentists Using a Hand Driver in a Limited Access Space Simulating the MouthJournal of Oral Implantology, 2007
- ACCURACY AND RELIABILITY OF TORQUE WRENCHES USED FOR HALO APPLICATION IN CHILDRENJournal of Bone and Joint Surgery, 2003
- Moments and Forces During Pedicle Screw InsertionSpine, 1998
- Effects of infection control procedures on the accuracy of a new mechanical torque wrench system for implant restorationsThe Journal of Prosthetic Dentistry, 1996
- ULTIMATE TENSILE STRENGTH OF FIVE INTERCHANGEABLE PROSTHETIC RETAINING SCREWSImplant Dentistry, 1996
- Geometric comparison of five interchangeable implant prosthetic retaining screwsThe Journal of Prosthetic Dentistry, 1995
- Comparison of "Look-Alike" Implant Prosthetic Retaining ScrewsJournal of Prosthodontics, 1995
- A Measurement of Torque Values Obtained With Hand‐Held Drivers in a Simulated Clinical SettingJournal of Prosthodontics, 1993
- PROVIDING OPTIMUM TORQUE TO IMPLANT PROSTHESESImplant Dentistry, 1993