Cross-Domain Unpaired Learning for Low-Dose CT Imaging
- 7 September 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27 (11) , 5471-5482
Abstract
Supervised deep-learning techniques with paired training datasets have been widely studied for low-dose computed tomography (LDCT) imaging with excellent performance. However, the paired training datasets are usually difficult to obtain in clinical routine, which restricts the wide adoption of supervised deep-learning techniques in clinical practices. To address this issue, a general idea is to construct a pseudo paired training dataset based on the widely available unpaired data, after which, supervised deep-learning techniques can be adopted for improving the LDCT imaging performance by training on the pseudo paired training dataset. However, due to the complexity of noise properties in CT imaging, the LDCT data are difficult to generate in order to construct the pseudo paired training dataset. In this paper, we propose a simple yet effective cross-domain unpaired learning framework for pseudo LDCT data generation and LDCT image reconstruction, which is denoted as CrossDuL. Specifically, a dedicated pseudo LDCT sinogram generative module is constructed based on a data-dependent noise model in the sinogram domain, and then instead of in the sinogram domain, a pseudo paired dataset is constructed in the image domain to train an LDCT image restoration module. To validate the effectiveness of the proposed framework, clinical datasets are adopted. Experimental results demonstrate that the CrossDuL framework can obtain promising LDCT imaging performance in both quantitative and qualitative measurements.Keywords
Funding Information
- National Natural Science Foundation of China (62001208, U21A6005, U1708261, 62001207)
This publication has 29 references indexed in Scilit:
- Image Blind Denoising with Generative Adversarial Network Based Noise Modeling2018
- FFDNet: Toward a Fast and Flexible Solution for CNN-Based Image DenoisingIEEE Transactions on Image Processing, 2018
- Robust Low-Dose CT Sinogram Preprocessing via Exploiting Noise-Generating MechanismIEEE Transactions on Medical Imaging, 2017
- Beyond a Gaussian Denoiser: Residual Learning of Deep CNN for Image DenoisingIEEE Transactions on Image Processing, 2017
- TU-FG-207A-04: Overview of the Low Dose CT Grand ChallengeMedical Physics, 2016
- Development and Validation of a Practical Lower-Dose-Simulation Tool for Optimizing Computed Tomography Scan ProtocolsJournal of Computer Assisted Tomography, 2012
- Computed Tomography — An Increasing Source of Radiation ExposureThe New England journal of medicine, 2007
- Properties of preprocessed sinogram data in x-ray computed tomographyMedical Physics, 2006
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004
- Single-slice rebinning method for helical cone-beam CTPhysics in Medicine & Biology, 1999