Model to estimate the trapping parameters of cross‐linked polyethylene cable peelings of different service years and their relationships with dc breakdown strengths
Authors:
Open Access
- 1 July 2016
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 1 (2) , 95-105
Abstract
In this study, an improved trapping/detrapping model was used to simulate the charge dynamics in cross‐linked polyethylene peelings from different‐year aged cables. Injection barrier of trapping parameters was estimated by the model fitted to experimental data for each type of sample. Moreover, dc breakdown tests were operated on those samples. It has been found that the dc breakdown strength of inner‐layer samples is the lowest in cable sections with thicker insulation layer taken from high‐voltage ac (HVAC) 220 kV service condition, whereas for the cable with thinner insulation from HVAC 110 kV, middle‐layer samples have worst breakdown performance. This might be explained by the space charge issues under long‐term HVAC condition. More importantly, a clear relationship between estimated model parameters, including injection barrier, trap depth and trap density, with the dc breakdown strength in each layer has been reported in this study.Keywords
This publication has 19 references indexed in Scilit:
- An improved model to estimate trapping parameters in polymeric materials and its application on normal and aged low-density polyethylenesJournal of Applied Physics, 2015
- Effect of electrical and thermal stressing on charge traps in XLPE cable insulationIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- Charge trapping and detrapping in polymeric materials: Trapping parametersJournal of Applied Physics, 2011
- Charge trapping and detrapping in polymeric materialsJournal of Applied Physics, 2009
- Decay of space charge in a glassy epoxy resin following voltage removalIEEE Transactions on Dielectrics and Electrical Insulation, 2006
- Description of bipolar charge transport in polyethylene using a fluid model with a constant mobility: model predictionJournal of Physics D: Applied Physics, 2003
- Dielectrics in Electric Fields2003
- Electrical Degradation and Breakdown in Polymers1992
- Steady-state conduction in linear low-density polyethylene with Poole-lowered trap depthIEEE Transactions on Electrical Insulation, 1990
- Electrical Properties of Polyethylene Single CrystalsJapanese Journal of Applied Physics, 1967