Clinical Soma and Neurite Density Imaging ( SANDI ): Translational Microstructure Mapping on Clinical 3T MRI Scanners
Open Access
- 27 August 2026
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (6) , 2780-2794
Abstract
Purpose: The Soma and Neurite Density Imaging (SANDI) model enables characterization of gray matter (GM) microstructure by estimating soma and neurite signal fractions, but its clinical applicability is limited by the need for multi‐shell acquisitions (at least five b ‐values up to 6000 s/mm 2 ), requiring high‐gradient MRI systems. We developed a clinically feasible SANDI model that reduces data requirements and model complexity while preserving sensitivity to cellular‐level microstructural features. Methods: Clinical SANDI incorporates biophysical constraints via fixed intra‐neurite diffusivity and a tortuosity relation from effective medium theory to estimate extracellular diffusivity from intracellular volume fractions, reducing the number of free parameters and data requirements. The model was validated using Monte Carlo diffusion simulations in GM‐like microenvironments and evaluated in vivo on the ultra‐high‐gradient 3 T Connectome 2.0 scanner ( G max = 500 mT/m, five‐shell, ∼19 min) and a clinical 3 T system ( G max = 80 mT/m, two‐shell, ∼7 min). Additional experiments across multiple gradient strengths, diffusion times, and sites assessed model robustness. Results: Diffusion simulations showed close agreement (Pearson r = 0.99) between simulated and theoretical extracellular diffusivity across varying intracellular volume fractions. With 500 mT/m gradients, clinical SANDI using two shells demonstrated strong correspondence with five‐shell standard SANDI ( r = 0.97, intraclass correlation coefficient = 0.94). Across reduced gradient strengths, clinical SANDI preserved cortical intra‐soma signal fraction values, whereas standard SANDI exhibited underestimation at gradient strengths below 80 mT/m. Conclusion: Clinical SANDI enables reliable cortical GM microstructure estimation on widely available clinical 3T scanners within feasible scan times, facilitating broader translation of advanced diffusion MRI methods for studying aging, neurodegeneration, and neurological disorders.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (P41EB015896)
- National Institute of Biomedical Imaging and Bioengineering (P41EB030006)
- National Institute of Biomedical Imaging and Bioengineering (U01EB026996)
- National Institute of Biomedical Imaging and Bioengineering (R01NS118187)
- National Institute of Biomedical Imaging and Bioengineering (U24NS137077)
- National Institute of Biomedical Imaging and Bioengineering (R21AG082377)
- National Institute of Biomedical Imaging and Bioengineering (R21AG085795)
- National Institute of Biomedical Imaging and Bioengineering (DP5OD031854)
- National Research Council of Science and Technology (GTL25071‐000)
- Ministry of Science and ICT, South Korea (26‐BR‐03‐02)
This publication has 74 references indexed in Scilit:
- Dependence of the Extra‐Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray MatterMagnetic Resonance in Medicine, 2026
- Overview of ADNI MRIAlzheimer's & Dementia, 2024
- Mapping tissue microstructure across the human brain on a clinical scanner with soma and neurite density image metricsHuman Brain Mapping, 2023
- Highly efficient head‐only magnetic field insert gradient coil for achieving simultaneous high gradient amplitude and slew rate at 3.0T (MAGNUS) for brain microstructure imagingMagnetic Resonance in Medicine, 2019
- Imaging brain microstructure with diffusion MRI: practicality and applicationsNMR in Biomedicine, 2017
- The role of diffusion MRI in neuroscienceNMR in Biomedicine, 2017
- New insights about time-varying diffusivity and its estimation from diffusion MRIMagnetic Resonance in Medicine, 2016
- Gibbs‐ringing artifact removal based on local subvoxel‐shiftsMagnetic Resonance in Medicine, 2015
- MRI quantification of non‐Gaussian water diffusion by kurtosis analysisNMR in Biomedicine, 2010
- Diffusional kurtosis imaging: The quantification of non‐gaussian water diffusion by means of magnetic resonance imagingMagnetic Resonance in Medicine, 2005