A simple method for HPLC retention time prediction: linear calibration using two reference substances
Open Access
- 19 June 2017
- journal article
- research article
- Published by Springer Nature in Chinese Medicine
- Vol. 12 (1) , 1-12
Abstract
Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (tR) and predicted tR in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of tR accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The tR of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.Keywords
Funding Information
- Youth Development Research Foundation of NIFDC (2013WA8)
- National Natural Foundation of China (CN) (81303214)
- National Major Scientific and Technological Special Project for “Significant New Drugs Development” (2014ZX09304307-002)
This publication has 22 references indexed in Scilit:
- Ruggedness and robustness of conversion factors in method of simultaneous determination of multi-components with single reference standardJournal of Chromatography A, 2011
- Evaluation of two approaches to characterise liquid chromatographic columns using pharmaceutical separationsJournal of Chromatography A, 2009
- Column selection for pharmaceutical analyses based on a column classification using four test parametersJournal of Pharmaceutical and Biomedical Analysis, 2007
- Facilitated column selection in pharmaceutical analyses using a simple column classification systemJournal of Chromatography A, 2006
- The hydrophobic-subtraction model of reversed-phase column selectivityJournal of Chromatography A, 2004
- Characterisation of reversed-phase liquid-chromatographic columns by chromatographic testsJournal of Chromatography A, 2004
- Column selectivity in reversed-phase liquid chromatographyJournal of Chromatography A, 2004
- Column selectivity in reversed-phase liquid chromatographyJournal of Chromatography A, 2004
- Characterisation of reversed-phase liquid chromatographic columns by chromatographic testsRational column classification by a minimal number of column test parametersJournal of Chromatography A, 2003
- Column selectivity in reversed-phase liquid chromatographyJournal of Chromatography A, 2003