Multimodal imaging guides surgical management in a preclinical spinal implant infection model
Authors:
- Stephen D. ZollerSZStephen D. Zoller
- Howard Y. ParkHPHoward Y. Park
- Tove OlafsenTOTove Olafsen
- Charles ZamilpaCZCharles Zamilpa
- Zachary D.C. BurkeZBZachary D.C. Burke
- Gideon BlumsteinGBGideon Blumstein
- William L. SheppardWSWilliam L. Sheppard
- Christopher D. HamadCHChristopher D. Hamad
- Kellyn R. HoriKHKellyn R. Hori
- Jen-Chieh TsengJTJen-Chieh Tseng
- Julie CzuprynaJCJulie Czupryna
- Craig McMannusCMCraig McMannus
Open Access
- 7 February 2019
- journal article
- research article
- Published by American Society for Clinical Investigation in JCI Insight
- Vol. 4 (3)
Abstract
Spine implant infections portend disastrous outcomes, as diagnosis is challenging and surgical eradication is at odds with mechanical spinal stability. Current imaging modalities can detect anatomical alterations and anomalies but cannot differentiate between infection and aseptic loosening, diagnose specific pathogens, or delineate the extent of an infection. Herein, a fully human monoclonal antibody 1D9, recognizing the immunodominant staphylococcal antigen A on the surface of Staphylococcus aureus , was assessed as a nuclear and fluorescent imaging probe in a preclinical model of S . aureus spinal implant infection, utilizing bioluminescently labeled bacteria to confirm the specificity and sensitivity of this targeting. Postoperative mice were administered 1D9 probe dual labeled with 89-zirconium ( 89 Zr) and a near infrared dye (NIR680) ( 89 Zr-NIR680-1D9), and PET-CT and in vivo fluorescence and bioluminescence imaging were performed. The 89 Zr-NIR680-1D9 probe accurately diagnosed both acute and subacute implant infection and permitted fluorescent image-guided surgery for selective debridement of infected tissue. Therefore, a single probe could noninvasively diagnose an infection and facilitate image-guided surgery to improve the clinical management of implant infections.Keywords
Funding Information
- National Institutes of Health (5K08AR069112-01)
- National Institutes of Health (T32AR059033)
- CONACyT (169643)
- CEC MSCI-ITN (713482)
- CEC MSCI-ITN (713660)
This publication has 51 references indexed in Scilit:
- Evaluation of Dynamic [18F]-FDG-PET Imaging for the Detection of Acute Post-Surgical Bone InfectionPLOS ONE, 2012
- Prevalence of Healthcare-Associated Infections in Acute Care Hospitals in Jacksonville, FloridaInfection Control & Hospital Epidemiology, 2012
- In vivo detection of Staphylococcus aureus endocarditis by targeting pathogen-specific prothrombin activationNature Medicine, 2011
- Mouse model of chronic post‐arthroplasty infection: Noninvasive in vivo bioluminescence imaging to monitor bacterial burden for long‐term studyJournal of Orthopaedic Research, 2011
- Healthcare associated infection: novel strategies and antimicrobial implants to prevent surgical site infectionThe Annals of The Royal College of Surgeons of England, 2010
- Risk factors for deep surgical site infections after spinal fusionEuropean Spine Journal, 2010
- p-Isothiocyanatobenzyl-desferrioxamine: a new bifunctional chelate for facile radiolabeling of monoclonal antibodies with zirconium-89 for immuno-PET imagingEuropean Journal of Nuclear Medicine and Molecular Imaging, 2009
- The diagnosis and management of infection following instrumented spinal fusionEuropean Spine Journal, 2007
- Characterization of IsaA and SceD, Two Putative Lytic Transglycosylases of Staphylococcus aureusJournal of Bacteriology, 2007
- Promising Role of 18-F-Fluoro-D-Deoxyglucose Positron Emission Tomography in Clinical Infectious DiseasesEuropean Journal of Clinical Microbiology & Infectious Diseases, 2002