Association of bioimpedance‐derived 50‐kHz phase angle as marker of body composition with electrical parameters regarding the Cole‐Cole model
- 30 June 2020
- journal article
- research article
- Published by Wiley in Therapeutic Apheresis and Dialysis
- Vol. 25 (2) , 166-178
Abstract
Our aim is to clarify the association of the bioelectrical impedance‐derived 50‐kHz phase angle (φ50) with electrical parameters regarding the Cole‐Cole model and clinical parameters. A total of 440 sets of bioelectrical impedance data from pre‐ and post‐hemodialysis from 157 patients were used. Resistance at infinite frequency (Rinf), resistance at 0 frequency (R0), capacitance of the cell membrane (Cm), and a parameter for the distribution of the time constant (α) were examined as electrical parameters. Normally hydrated lean tissue mass as a percentage of the dry weight (PNHLT), excess fluid mass as a percentage of the dry weight (PExF), body mass index (BMI), age, and sex (Nsex, 0 for male, 1 for female) were examined as clinical parameters. φ50 increased with the decrease in Rinf/R0 and α and also with the increase in Cm (multiple regression coefficients [β]: pre/post, −0.886/−0.936, −0.175/−0.212, and 0.167/0.141), which determined the ratio of intra‐ to extracellular fluid volume (ICV/ECV), tissue homogeneity, and total cell mass. φ50 increased with an increase in PNHLT and BMI and decrease in PExF, Nsex, and age (β: pre/post, 0.654/0.581, 0.466/0.412, −0.483/−0.473, −0.216/−0.154, and −0.145/−0.127). The concordance correlation coefficient between φ50 for pre‐ and post‐hemodialysis (ρ = 0.772) may be improved (ρ = 0.950) by adding a multiplication of 0.2 and PExF to φ50 for correction. φ50 may be used to estimate body composition through the association with ICV/ECV, tissue homogeneity, and total cell mass. The correction for excess fluid is essential in order to use φ50 as a marker of body composition related to nutrition.Keywords
This publication has 26 references indexed in Scilit:
- Bioelectrical impedance phase angle relates to function, disease severity and prognosis in stable chronic obstructive pulmonary diseaseClinical Nutrition, 2015
- Effect of change in fluid distribution in segments in hemodialysis patients at different ultrafiltration rates on accuracy of whole body bioimpedance measurementJournal of Applied Physiology, 2014
- Investigation of the freely available easy-to-use software ‘EZR’ for medical statisticsBone Marrow Transplantation, 2012
- Is there any survival advantage of obesity in Southern European haemodialysis patients?Nephrology Dialysis Transplantation, 2009
- Importance of Whole-Body Bioimpedance Spectroscopy for the Management of Fluid BalanceBlood Purification, 2009
- Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methodsMedical Engineering & Physics, 2008
- Hypoalbuminemia is Also a Marker of Fluid Excess Determined by Bioelectrical Impedance Parameters in Dialysis PatientsTherapeutic Apheresis and Dialysis, 2007
- Body fluid volume determination via body composition spectroscopy in health and diseasePhysiological Measurement, 2006
- A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedanceKidney International, 2002
- Unproved prediction of extracellular and total body water using impedance loci generated by multiple frequency bioelectrical impedance analysisPhysics in Medicine & Biology, 1993