Differences of Longitudinal Chromatic Aberration (LCA) between Eyes with Intraocular Lenses from Different Manufacturers
Open Access
- 3 June 2016
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (6) , e0156227
Abstract
Several researchers have studied the longitudinal chromatic aberration (LCA) of eyes implanted with an intraocular lens (IOL). We investigated the LCA of eyes implanted with yellow-colored IOLs from three different manufacturers: Alcon Inc., HOYA Corp., and AMO Inc. The number of subjects was 11, 16, and 16, respectively. The LCA of eyes implanted with SN60WF and SN60AT (Alcon Inc.), and with XY-1 (HOYA Corp.), was the same as that of phakic eyes. The LCA of eyes with ZCB00V (AMO Inc.) was smaller than that of phakic eyes. The LCA of eyes implanted with Alcon’s and HOYA’s IOLs, but not the LCA of eyes implanted with AMO’s IOLs, was positively correlated with the powers of the IOLs. We also performed simulations to verify the impacts of LCA on visual performance for 4-mm pupil diameter; the simulations were a polychromatic modulation transfer function (MTF) and a visual Strehl ratio computed on the basis of an optical transfer function (VSOTF). We concluded that the differences between the LCA of different manufacturers do not affect visual performances when some extent of higher-order aberration (HOA) exists. The smaller HOA of AMO IOLs may enhance visual performance.Keywords
Funding Information
- Topcon Corp.
- Topcon Corp.
- Topcon Corp.
This publication has 38 references indexed in Scilit:
- Study on chromatic aberration in a population of Chinese myopic eyes by means of optical designBiomedical Optics Express, 2013
- Ocular aberrations up to the infrared range: from 6328 to 1070 nmOptics Express, 2008
- On the Longitudinal Chromatic Aberration of the Intraocular LensesOptometry and Vision Science, 2007
- The effect of chromatic dispersion on pseudophakic optical performanceBritish Journal of Ophthalmology, 2007
- Serial Measurements of Higher-Order Aberrations after Blinking in Normal SubjectsInvestigative Ophthalmology & Visual Science, 2006
- A luminous efficiency function,V*(λ), for daylight adaptationJournal of Vision, 2005
- Ocular aberrations as a function of wavelength in the near infrared measured with a femtosecond laserOptics Express, 2005
- Radius measurement by interferometryOptical Engineering, 1992
- Refractive index of water and steam as function of wavelength, temperature and densityJournal of Physical and Chemical Reference Data, 1990
- Axial Chromatic Aberration of the Human EyeJournal of the Optical Society of America, 1957