Fast dose calculation in magnetic fields withGPUMCD
Authors:
- S HissoinySHS Hissoiny
- A J E RaaijmakersARA J E Raaijmakers
- B OzellBOB Ozell
- P DesprésPDP Després
- B W RaaymakersBRB W Raaymakers
- 20 July 2011
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (16) , 5119-5129
Abstract
A new hybrid imaging-treatment modality, the MRI-Linac, involves the irradiation of the patient in the presence of a strong magnetic field. This field acts on the charged particles, responsible for depositing dose, through the Lorentz force. These conditions require a dose calculation engine capable of taking into consideration the effect of the magnetic field on the dose distribution during the planning stage. Also in the case of a change in anatomy at the time of treatment, a fast online replanning tool is desirable. It is improbable that analytical solutions such as pencil beam calculations can be efficiently adapted for dose calculations within a magnetic field. Monte Carlo simulations have therefore been used for the computations but the calculation speed is generally too slow to allow online replanning. In this work, GPUMCD, a fast graphics processing unit (GPU)-based Monte Carlo dose calculation platform, was benchmarked with a new feature that allows dose calculations within a magnetic field. As a proof of concept, this new feature is validated against experimental measurements. GPUMCD was found to accurately reproduce experimental dose distributions according to a 2%-2 mm gamma analysis in two cases with large magnetic field-induced dose effects: a depth-dose phantom with an air cavity and a lateral-dose phantom surrounded by air. Furthermore, execution times of less than 15 s were achieved for one beam in a prostate case phantom for a 2% statistical uncertainty while less than 20 s were required for a seven-beam plan. These results indicate that GPUMCD is an interesting candidate, being fast and accurate, for dose calculations for the hybrid MRI-Linac modality.Keywords
This publication has 14 references indexed in Scilit:
- GPUMCD: A new GPU‐oriented Monte Carlo dose calculation platformMedical Physics, 2011
- GPU-based ultrafast IMRT plan optimizationPhysics in Medicine & Biology, 2009
- First MR images obtained during megavoltage photon irradiation from a prototype integrated linac‐MR systemMedical Physics, 2009
- Magnetic-field-induced dose effects in MR-guided radiotherapy systems: dependence on the magnetic field strengthPhysics in Medicine & Biology, 2008
- MRI/linac integrationRadiotherapy and Oncology, 2008
- Experimental verification of magnetic field dose effects for the MRI-acceleratorPhysics in Medicine & Biology, 2007
- Magnetic confinement of electron and photon radiotherapy dose: A Monte Carlo simulation with a nonuniform longitudinal magnetic fieldMedical Physics, 2005
- Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose increase at tissue–air interfaces in a lateral magnetic field due to returning electronsPhysics in Medicine & Biology, 2005
- The effect of dose calculation uncertainty on the evaluation of radiotherapy plansMedical Physics, 2000
- A technique for the quantitative evaluation of dose distributionsMedical Physics, 1998