Long-term stability of cardiac function in normal and chronically failing mouse hearts in a vertical-bore MR system
- 8 November 2004
- journal article
- research article
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 17 (3-6) , 162-169
Abstract
We previously demonstrated stability of ventricular volumes and cardiac function in normal and in chronically failing mouse hearts in MR systems with a vertical-bore magnet for up to 1 h. However, in order to exploit the benefits of an increased magnetic field strength of these MR systems in more time-consuming studies required by, for example MR spectroscopy, we investigated whether cardiac function and ventricular volumes of healthy and infarcted mice would be affected in vertical position over a prolonged period. We applied high-resolution MR cine imaging on an 11.7 T vertical MR system to monitor cardiac functional parameters of normal and chronically failing mouse hearts over a period of 3 h in an upright position, with a temporal resolution of ≤15 min. We monitored left-ventricular volumes and cardiac functional parameters in both groups. In normal mice, we detected a decrease of left-ventricular end-systolic volumes by 8 μl and an approximately 23% increase of ejection fraction over time indicating a small but detectable degree of orthostatic dysregulation. Observed changes were more pronounced in mice with heart failure. Despite significant changes in left-ventricular volumes and function, absolute values measured for all functional cardiac parameters are consistent with near-physiological conditions. Thus, mice can be studied in high-field MR systems positioned vertically for 3 h.Keywords
This publication has 27 references indexed in Scilit:
- Transgenic rescue of neurogenic atrophy in the nmd mouse reveals a role for Ighmbp2 in dilated cardiomyopathyHuman Molecular Genetics, 2004
- Nitric Oxide Mediates Benefits of Angiotensin II Type 2 Receptor Overexpression During Post-Infarct RemodelingHypertension, 2004
- T‐box transcription factor Tbx2 represses differentiation and formation of the cardiac chambersDevelopmental Dynamics, 2004
- Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fieldsJournal of Magnetic Resonance Imaging, 2004
- High‐resolution myocardial perfusion mapping in small animals in vivo by spin‐labeling gradient‐echo imagingMagnetic Resonance in Medicine, 2003
- Assessment of global and regional myocardial function in the mouse using cine and tagged MRIMagnetic Resonance in Medicine, 2003
- Angiotensin II Type 2 Receptor Overexpression Preserves Left Ventricular Function After Myocardial InfarctionCirculation, 2002
- An increase in the myocardial PCr/ATP ratio in GLUT4 null miceThe FASEB Journal, 2002
- Noninvasive quantification of total sodium concentrations in acute reperfused myocardial infarction using 23Na MRIMagnetic Resonance in Medicine, 2001
- Digital Image ProcessingLeonardo, 1981