MPC design for rapid pump-attenuation and expedited hyperglycemia response to treat T1DM with an Artificial Pancreas
- 1 June 2014
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2014 (07431619) , 4224-4230
Abstract
The design of a Model Predictive Control (MPC) strategy for the closed-loop operation of an Artificial Pancreas (AP) for treating Type 1 Diabetes Mellitus (T1DM) is considered in this paper. The contribution of this paper is to propose two changes to the usual structure of the MPC problems typically considered for control of an AP. The first proposed change is to replace the symmetric, quadratic input cost function with an asymmetric, quadratic function, allowing negative control inputs to be penalized less than positive ones. This facilitates rapid pump-suspensions in response to predicted hypoglycemia, while simultaneously permitting the design of a conservative response to hyperglycemia. The second proposed change is to penalize the velocity of the predicted glucose level, where this velocity penalty is based on a cost function that is again asymmetric, but additionally state-dependent. This facilitates the accelerated response to acute, persistent hyperglycemic events, e.g., as induced by unannounced meals. The novel functionality is demonstrated by numerical examples, and the efficacy of the proposed MPC strategy verified using the University of Padova/Virginia metabolic simulator.Keywords
This publication has 24 references indexed in Scilit:
- Multivariable Adaptive Closed-Loop Control of an Artificial Pancreas Without Meal and Activity AnnouncementDiabetes Technology & Therapeutics, 2013
- Fully Integrated Artificial Pancreas in Type 1 DiabetesDiabetes, 2012
- Artificial Pancreas: Past, Present, FutureDiabetes, 2011
- Model predictive control of glucose concentration in type I diabetic patients: An in silico trialBiomedical Signal Processing and Control, 2009
- Multi-objective blood glucose control for type 1 diabetesMedical & Biological Engineering & Computing, 2009
- A feedforward–feedback glucose control strategy for type 1 diabetes mellitusJournal of Process Control, 2008
- Feasibility of Automating Insulin Delivery for the Treatment of Type 1 DiabetesDiabetes, 2006
- Continuous glucose monitoring and closed‐loop systemsDiabetic Medicine, 2005
- Glucose control design using nonlinearity assessment techniquesAIChE Journal, 2005
- Control of systems integrating logic, dynamics, and constraintsAutomatica, 1999