Quality assurance tests for the Gamma Knife® Icon™ image guidance system
Open Access
- 3 August 2018
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (5) , 573-579
Abstract
Introduction: The Gamma Knife® Icon™ comes with an image guidance system for tracking patient motion and correcting for inter‐ and intrafractional shifts, mainly used with frameless thermoplastic immobilization. The system consists of a cone‐beam CT (CBCT) and a couch‐mounted infrared camera (IFMM). We report our quality assurance program for Icon's image guidance system.Methods: The manufacturer‐provided tool is used for daily checks of CBCT positional precision. Catphan® phantom is used for monthly checks of CBCT image qualities (uniformity, contrast to noise ratio (CNR), and spatial resolution) for the two acquisition presets (low‐dose and high‐quality presets). On a semi‐annual schedule, we use a frame tool to check the agreement of CBCT‐based and Frame‐based stereotactic space coordinates by comparing the locations of five attached ball bearings in CT‐sim scans (Frame‐based coordinates determination) and in Icon's CBCT scans. On an annual basis, the accuracy of IFMM, image registration, and delivery‐after‐shift are tested using a translational stage. A weighted CT dose index is measured annually with a pencil chamber in CTDI head phantom.Results: The CBCT precision check: 0.12 ± 0.04 mm (maximum deviations average). CBCT image quality: spatial resolution range: [6,7] lp/cm (low), and [7,8] lp/cm (high); uniformity: 12.82 ± 0.69% (low), and 13.01 ± 0.69% (high); CNR: 1.07 ± 0.08 (low), and 1.69 ± 0.10 (high). Agreement of CBCT‐based with Frame‐based stereotactic coordinates range: [0.33, 0.66] mm. Accuracy of IFMM: 0.00 ± 0.12 mm (average) with 0.27 mm (max.); image registration: 0.03 ± 0.06 mm (average) with 0.23 mm (max.); and delivery‐after‐shift: 0.24 ± 0.09 mm (average) with 0.42 mm (max.). CTDIw: 2.3 mGy (low), and 5.7 mGy (high).Conclusions: The manufacturer‐required QA checks together with additional user‐defined checks are an important combination for a robust quality assurance program ensuring the safe use of Gamma Knife® Icon™'s image guidance and motion management features.Keywords
This publication has 8 references indexed in Scilit:
- Assessment of image co-registration accuracy for frameless gamma knife surgeryPLOS ONE, 2018
- Evaluation of stability of stereotactic space defined by cone‐beam CT for the Leksell Gamma Knife IconJournal of Applied Clinical Medical Physics, 2017
- Commissioning of the Leksell Gamma Knife® Icon™Medical Physics, 2017
- Validity of the use of nose tip motion as a surrogate for intracranial motion in mask-fixated frameless Gamma Knife® Icon™ therapy.2017
- 25. End-to-end tests of the new Elekta gamma knife ICONPhysica Medica, 2016
- Evaluation of the effect of silicone breast inserts on X-ray mammography and breast tomosynthesis images: A Monte Carlo simulation studyPhysica Medica, 2016
- Quality assurance for image‐guided radiation therapy utilizing CT‐based technologies: A report of the AAPM TG‐179Medical Physics, 2012
- Task Group 142 report: Quality assurance of medical acceleratorsa)Medical Physics, 2009