Characteristics of inverse gamma histograms
Authors:
- 27 May 2020
- journal article
- research article
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 43 (2) , 659-664
Abstract
This work explores the characteristics of the inverse gamma histogram and its potential use as part of the patient specific quality assurance (PSQA) program for volumetric modulated arc therapy (VMAT). ArcCheck measured dose files and TPS predicted dose files were imported and analysed using the in-house inverse gamma code developed in the Python package. Inverse gamma with fixed distance-to-agreement of 2 mm were calculated for 23 VMAT arcs. Dose difference histograms were plotted for six arbitrarily selected arcs with the 95th and 90th percentile values calculated. Dose difference histograms enabled visualisation of the dose difference distribution information. The 95th and 90th percentile values are equivalent to the dose difference criteria where the gamma pass rate is 95% and 90% respectively. These values can be used as a guide to assess plan acceptability, especially for plans that failed the initial gamma evaluation. The inverse gamma histograms are demonstrated to be a useful tool for plan evaluation in addition to the traditional gamma evaluation method. It contains dose difference or distance-to-agreement distribution information, which could be clinically useful for plan evaluation.Keywords
This publication has 26 references indexed in Scilit:
- Tolerance limits and methodologies forIMRTmeasurement‐based verificationQA:Recommendations ofAAPMTask Group No. 218Medical Physics, 2018
- Pretreatment patient‐specific IMRT quality assurance: A correlation study between gamma index and patient clinical dose volume histogramMedical Physics, 2012
- State of the art on dose prescription, reporting and recording in Intensity-Modulated Radiation Therapy (ICRU report No. 83)Cancer/Radiothérapie, 2011
- Per‐beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errorsMedical Physics, 2011
- Patient‐specific quality assurance method for VMAT treatment deliveryMedical Physics, 2009
- Intensity modulation with photons for benign intracranial tumours: A planning comparison of volumetric single arc, helical arc and fixed gantry techniquesRadiotherapy and Oncology, 2008
- A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapyRadiotherapy and Oncology, 2008
- On dose distribution comparisonPhysics in Medicine & Biology, 2006
- A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluationRadiotherapy and Oncology, 2002
- A technique for the quantitative evaluation of dose distributionsMedical Physics, 1998