An in situ probe‐spacing‐correction thermo‐TDR sensor to measure soil water content accurately

Authors:

Abstract
Summary: To reduce the possibility of probe deflections, conventional thermo‐time domain reflectometry (T‐TDR) sensors have relatively short probe lengths (≤4 cm). However, short probes lead to large errors in TDR‐estimated soil water content ( θ v ). In this study, two new 6‐cm‐long probe‐spacing‐correction T‐TDR (CT‐TDR) sensors were investigated. Compared with conventional 4‐cm‐long T‐TDR sensors, the 6‐cm‐long CT‐TDR sensors reduced errors in TDR‐estimated θ v . Errors in heat pulse (HP)‐estimated θ v because of probe deflections were reduced when linear or nonlinear probe‐spacing‐correction algorithms were implemented. The 6‐cm‐long CT‐TDR sensors provided more accurate θ v estimations than do the conventional 4‐cm‐long T‐TDR sensors. Highlights: Short thermo‐TDR sensor has shortcomings in determining soil water content. Changes in thermo‐TDR probe spacing caused by deflections can be determined in situ . Correcting changed thermo‐TDR probe spacing determined soil water content accurately. The 6‐cm‐long thermo‐TDR sensors determined soil water content more accurately than 4‐cm‐long sensors.
Funding Information
  • China Scholarship Council (201606350315)
  • National Natural Science Foundation of China (41771257)

This publication has 19 references indexed in Scilit: