Evaluation of Chemo‐ and Photo‐toxicity of a Live Fluorescent Dye for Cell Analysis
- 4 December 2020
- journal article
- research article
- Published by Wiley in Photochemistry and Photobiology
- Vol. 97 (2) , 448-452
Abstract
Live cell imaging is used to track the dynamic adaptation of cell size and motility to various external factors. Bright‐field configuration can be used for these experiments; however, the analysis can be challenging and difficult to automate. In this direction, a superior alternative is represented by the use of live cell dyes, which provide intense fluorescence from subcellular structures of living cells. Yet, the potential chemo‐ and photo‐toxicity of the fluorophores poses the necessity of an accurate protocol optimization to avoid artefacts. Toxicity studies generally focus on cell proliferation and apoptosis, neglecting the cellular activities under investigation. Here, we present the case of SYTO 13 in combination with primary endothelial cells. The optimization of the staining procedure is tested comparing cell proliferation and motility rate. In addition, the combined effect of staining and fluorescent illumination, reporting for photochemical toxicity, is evaluated. We demonstrate that while cell viability and proliferation are mainly unaffected by the staining and imagining protocols, a significant reduction of the motility rate is induced both by the chemical dye alone and in combination with fluorescent illumination. The general implications for this procedure are discussed.Keywords
This publication has 16 references indexed in Scilit:
- Live cell imaging shows hepatocyte growth factor-induced Met dimerizationBiochimica et Biophysica Acta (BBA) - Molecular Cell Research, 2016
- SYTO-13, a Viability Marker as a New Tool to Monitor In Vitro Pharmacodynamic Parameters of Anti-Pneumocystis DrugsPLOS ONE, 2015
- The influence of surface micro-structure on endothelialization under supraphysiological wall shear stressBiomaterials, 2014
- Toward a Rational Design of Surface Textures Promoting EndothelializationNano Letters, 2014
- Cell Image Velocimetry (CIV): boosting the automated quantification of cell migration in wound healing assaysIntegrative Biology, 2012
- Compatibility of SYTO 13 and Hoechst 33342 for longitudinal imaging of neuron viability and cell deathBMC Research Notes, 2012
- Optically Stable Biocompatible Flame-Made SiO2-Coated Y2O3:Tb3+ Nanophosphors for Cell ImagingACS Nano, 2012
- Phosphorylation of VE-cadherin is modulated by haemodynamic forces and contributes to the regulation of vascular permeability in vivoNature Communications, 2012
- Use of SYTO 13, a fluorescent dye binding nucleic acids, for the detection of microparticles in in vitro systemsCytometry Part A, 2010
- Cell Spreading and Focal Adhesion Dynamics Are Regulated by Spacing of Integrin LigandsBiophysical Journal, 2007