Changes in Ocular Response Analyzer Parameters After LASIK
Authors:
- Ding ChenDCDing Chen
- Jianhua WangJWJianhua Wang
- Fan LuFLFan Lu
- Qinmei WangQWQinmei Wang
- Jia QuJQJia Qu
- 1 April 2010
- journal article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 26 (4) , 279-288
Abstract
To investigate changes in Ocular Response Analyzer parameters after myopic LASIK.Thirty myopic patients (60 eyes) undergoing bilateral LASIK were studied prospectively. Corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated IOP (IOPcc) measurements were obtained with the Ocular Response Analyzer before and after LASIK. Central corneal thickness and corneal flap thickness were also measured with optical coherence tomography.Compared with preoperative baseline values, corneal hysteresis, corneal resistance factor, IOPg, IOPcc, and central corneal thickness decreased postoperatively (P<.01). Corneal hysteresis (CH), corneal resistance factor (CRF), IOPg, IOPcc, and central corneal thickness (CCT) increased between 10 days and 3 months (post-hoc, P<.05). (The differences between the preoperative values and those at 3 months postoperatively are denoted by Delta.) The correlation of the ablation depth was stronger for DeltaCRF (r=0.457) than for DeltaCH (r=0.271). DeltaCH was negatively correlated to flap thickness (r=-0.361) and the ratio of flap thickness to preoperative central corneal thickness (r=-0.442) whereas DeltaCRF was not. DeltaCH was positively correlated with DeltaIOPcc, and DeltaCRF was positively correlated with DeltaIOPg. DeltaIOPg was positively correlated with DeltaCCT whereas DeltaIOPcc was not.Corneal biomechanical properties measured by corneal hysteresis and corneal resistance factor were decreased at 10 days after LASIK. Minimal recovery (approximately 10% of the changes) was achieved by 3 months. The changes in biomechanical properties may affect IOP measurement.Keywords
This publication has 31 references indexed in Scilit:
- Corneal hysteresis using the Reichert ocular response analyser: findings pre‐ and post‐LASIK and LASEKActa Ophthalmologica, 2008
- Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyesJournal of Cataract & Refractive Surgery, 2007
- Corneal Hysteresis and Intraocular Pressure Measurement in Children Using the Reichert Ocular Response AnalyzerAmerican Journal of Ophthalmology, 2006
- Effect of 24-Hour Corneal Biomechanical Changes on Intraocular Pressure MeasurementInvestigative Ophthalmology & Visual Science, 2006
- The Repeatability of Corneal and Corneal Epithelial Thickness Measurements Using Optical Coherence TomographyOptometry and Vision Science, 2006
- Dynamic corneal imagingJournal of Cataract & Refractive Surgery, 2005
- Influence of corneal biomechanical properties on intraocular pressure measurementJournal of Cataract & Refractive Surgery, 2005
- The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomographyAmerican Journal of Ophthalmology, 2002
- Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatismOphthalmology, 2000
- Strip Extensiometry for Comparison of the Mechanical Response of Bovine, Rabbit, and Human CorneasJournal of Biomechanical Engineering, 1992