Pulse current injection platform with consecutive early-time and intermediate-time high-altitude electromagnetic pulse conducted currents for immunity test of electrical equipment
- 1 November 2024
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
Abstract
High-altitude electromagnetic pulse (HEMP) has attracted considerable attention for its influence on electrical equipment. HEMP is divided into three parts: early time HEMP (E1), intermediate-time HEMP (E2), and late-time HEMP (E3). Most studies focused on E1 alone, while few investigated others. However, the electrical equipment may be disturbed by more than one part since these three parts co-exist in a HEMP environment. The pulse current injection (PCI) test is an effective immunity test method for evaluating the sensitivity and susceptibility of electrical equipment. To investigate the responses of electrical equipment excited by the consecutive E1 and E2 and compare with those under the individual E1 or E2, this paper builds a PCI platform that can carry out PCI tests with the consecutive E1 and E2 conducted current. To output the E1 current and the E2 current consecutively, which exhibit significant differences in the rise time (20 ns and 1.5 μs), peak current (2500 and 250 A), and full width at half maximum (FWHM, 500–550 ns and 3–5 ms), an E1&E2 coupler with a fast-closing high-current trigger switch is designed in this paper. Finally, some 10-kV epoxy insulators are tested in the developed platform, which shows the capacity of the proposed platform to test the immunity of electrical equipment with the consecutive E1 and E2 conducted current.Keywords
This publication has 15 references indexed in Scilit:
- Laser produced electromagnetic pulses: generation, detection and mitigationHigh Power Laser Science and Engineering, 2020
- On the HEMP environment for protective relaysIEEE Transactions on Power Delivery, 1994
- Impacts of a nominal nuclear electromagnetic pulse on electric power systems: a probabilistic approachIEEE Transactions on Power Delivery, 1991
- Transient response of a distribution circuit recloser and control unit to a high-altitude electromagnetic pulse (HEMP) and lightningIEEE Transactions on Electromagnetic Compatibility, 1990
- Flashover vulnerability of transmission and distribution lines to high-altitude electromagnetic pulse (HEMP)IEEE Transactions on Power Delivery, 1990
- Experimental determination of the effects of steep front-short duration surges on 25 kVA pole mounted distribution transformersIEEE Transactions on Power Delivery, 1989
- Extrapolation of measured power system response data to high-altitude EMP excitationIEEE Transactions on Electromagnetic Compatibility, 1988
- On the electromagnetic pulse produced by nuclear explosionsIEEE Transactions on Antennas and Propagation, 1978
- Detection of the Electromagnetic Radiation from Nuclear Explosions in SpacePhysical Review B, 1965
- Electromagnetic Radiation from a Nuclear Explosion in SpacePhysical Review B, 1962