Development of two‐dimensional gas chromatography (GC×GC) coupled with Orbitrap‐technology‐based mass spectrometry: Interest in the identification of biofuel composition
- 5 January 2020
- journal article
- research article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 55 (3) , e4495
Abstract
Comprehensive gas chromatography (GC) has emerged in recent years as the technique of choice for the analysis of volatile and semivolatile compounds in complex matrices. Coupling it with high‐resolution mass spectrometry (MS) makes a powerful tool for identification and quantification of organic compounds. The results obtained in this study showed a significant improvement by using GC×GC‐EI‐MS in comparison with GC‐EI‐MS; the separation of chromatogram peaks was highly improved, which facilitated detection and identification. However, the limitation of Orbitrap mass analyzer compared with time‐of‐flight analyzer is the data acquisition rate; the frequency average was about 25 Hz at a mass resolving power of 15.000, which is barely sufficient for the proper reconstruction of the narrowest chromatographic peaks. On the other hand, the different spectra obtained in this study showed an average mass accuracy of about 1 ppm. Within this average mass accuracy, some reasonable elemental compositions can be proposed and combined with characteristic fragment ions, and the molecules can be identified with precision. At a mass resolving power of 7.500, the scan rate reaches 43 Hz and the GC×GC‐MS peaks can be represented by more than 10 data points, which should be sufficient for quantification. The GC×GC‐MS was also applied to analyze a cellulose bio‐oil sample. Following this, a highly resolved chromatogram was obtained, allowing EI mass spectra containing molecular and fragment ions of many distinct molecules present in the sample to be identified.Keywords
Funding Information
- Conseil Régional de Haute Normandie
This publication has 35 references indexed in Scilit:
- Pyrolysis Two-Dimensional GC-MS of Miscanthus Biomass: Quantitative Measurement Using an Internal Standard MethodEnergy & Fuels, 2017
- Comparison of cryogenic and differential flow (forward and reverse fill/flush) modulators and applications to the analysis of heavy petroleum cuts by high-temperature comprehensive gas chromatographyJournal of Chromatography A, 2015
- Comprehensive two‐dimensional gas chromatography‐mass spectrometry: Recent evolution and current trendsMass Spectrometry Reviews, 2014
- Effects of Weathering on Sterol, Fatty Acid Methyl Ester (FAME), and Hydrocarbon Profiles of Biodiesel and Biodiesel/Diesel BlendsEnvironmental Forensics, 2013
- Top ten fundamental challenges of biomass pyrolysis for biofuelsEnergy & Environmental Science, 2012
- Comprehensive two-dimensional gas chromatography in combination with rapid scanning quadrupole mass spectrometry in perfume analysisJournal of Chromatography A, 2005
- Comprehensive two-dimensional gas chromatography: a powerful and versatile analytical toolJournal of Chromatography A, 2003
- An Overview of Biomass PyrolysisEnergy Sources, 2002
- Comparison of Thermal Sweeper and Cryogenic Modulator Technology for Comprehensive Gas ChromatographyJournal of High Resolution Chromatography, 2000
- Comprehensive Two-Dimensional Gas Chromatography with Mass Spectrometric Detection (GC × GC/MS) Applied to the Analysis of PetroleumJournal of High Resolution Chromatography, 1999