Development of SI-traceable C-peptide certified reference material NMIJ CRM 6901-a using isotope-dilution mass spectrometry-based amino acid analyses
- 20 May 2012
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 404 (1) , 13-21
Abstract
A certified reference material (CRM) is a higher-order calibration material used to enable a traceable analysis. This paper describes the development of a C-peptide CRM (NMIJ CRM 6901-a) by the National Metrology Institute of Japan using two independent methods for amino acid analysis based on isotope-dilution mass spectrometry. C-peptide is a 31-mer peptide that is utilized for the evaluation of β-cell function in the pancreas in clinical testing. This CRM is a lyophilized synthetic peptide having the human C-peptide sequence, and contains deamidated and pyroglutamylated forms of C-peptide. By adding water (1.00 ± 0.01) g into the vial containing the CRM, the C-peptide solution in 10 mM phosphate buffer saline (pH 6.6) is reconstituted. We assigned two certified values that represent the concentrations of total C-peptide (mixture of C-peptide, deamidated C-peptide, and pyroglutamylated C-peptide) and C-peptide. The certified concentration of total C-peptide was determined by two amino acid analyses using pre-column derivatization liquid chromatography–mass spectrometry and hydrophilic chromatography–mass spectrometry following acid hydrolysis. The certified concentration of C-peptide was determined by multiplying the concentration of total C-peptide by the ratio of the relative area of C-peptide to that of the total C-peptide measured by liquid chromatography. The certified value of C-peptide (80.7 ± 5.0) mg/L represents the concentration of the specific entity of C-peptide; on the other hand, the certified value of total C-peptide, (81.7 ± 5.1) mg/L can be used for analyses that does not differentiate deamidated and pyroglutamylated C-peptide from C-peptide itself, such as amino acid analyses and immunochemical assays.Keywords
This publication has 16 references indexed in Scilit:
- Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes MellitusClinical Chemistry, 2011
- Quantification of protein calibrants by amino acid analysis using isotope dilution mass spectrometryAnalytical Biochemistry, 2011
- Application of amino acid analysis using hydrophilic interaction liquid chromatography coupled with isotope dilution mass spectrometry for peptide and protein quantificationJournal of Chromatography B, 2009
- Standardization of C-Peptide MeasurementsClinical Chemistry, 2008
- Toward Système International d’Unité-traceable protein quantification: From amino acids to proteinsAnalytical Biochemistry, 2008
- Direct sensitive quantitative LC/MS analysis of C‐peptide from human urine by two dimensional reverse phase/reverse phase high‐performance liquid chromatographyJournal of Separation Science, 2006
- Phosphopeptide Sequencing by In-Source Decay Spectrum in Delayed Extraction Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass SpectrometryAnalytical Biochemistry, 2000
- Contributions of mass spectrometry to peptide and protein structureJournal of Mass Spectrometry, 1988
- Quantitation of human pancreatic beta-cell function by immunoassay of C-peptide in urineDiabetes, 1977
- Insulin Biosynthesis: Evidence for a PrecursorScience, 1967