A Retrospective Analysis of Pedicle Screw Placement Accuracy Using the ExcelsiusGPS Robotic Guidance System: Case Series
Authors:
- 28 November 2022
- journal article
- research article
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 24 (3) , 242-247
Abstract
BACKGROUND: Robotic guidance has become widespread in spine surgery. Although the intent is improved screw placement, further system-specific data are required to substantiate this intention for pedicle screws in spinal stabilization constructs. OBJECTIVE: To determine the accuracy of pedicle screws placed with the aid of a robot in a cohort of patients immediately after the adoption of the robot-assisted surgery technique. METHODS: A retrospective, Institutional Review Board–approved study was performed on the first 100 patients at a single facility, who had undergone spinal surgeries with the use of robotic techniques. Pedicle screw accuracy was graded using the Gertzbein–Robbins Scale based on pedicle wall breach, with grade A representing 0 mm breach and successive grades increasing breach thresholds by 2 mm increments. Preoperative and postoperative computed tomography scans were also used to assess offsets between the objective plan and true screw placements. RESULTS: A total of 326 screws were analyzed among 72 patients with sufficient imaging data. Ages ranged from 21 to 84 years. The total accuracy rate based on the Gertzbein–Robbins Scale was 97.5%, and the rate for each grade is as follows: A, 82%; B, 15.5%; C, 1.5%; D, 1%; and E, 0. The average tip offset was 1.9 mm, the average tail offset was 2.0 mm, and the average angular offset was 2.6°. CONCLUSION: Robotic-assisted surgery allowed for accurate implantation of pedicle screws on immediate adoption of this technique. There were no complications attributable to the robotic technique, and no hardware revisions were required.Keywords
This publication has 40 references indexed in Scilit:
- Robot-assisted spine surgery: feasibility study through a prospective case-matched analysisEuropean Spine Journal, 2015
- Robot-assisted and fluoroscopy-guided pedicle screw placement: a systematic reviewEuropean Spine Journal, 2013
- A review of surgical robots for spinal interventionsThe International Journal of Medical Robotics and Computer Assisted Surgery, 2012
- Accuracy of Robot-Assisted Placement of Lumbar and Sacral Pedicle ScrewsSpine, 2012
- Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placementEuropean Spine Journal, 2011
- Clinical Acceptance and Accuracy Assessment of Spinal Implants Guided With SpineAssist Surgical RobotSpine, 2010
- "Free-hand" technique for thoracolumbar pedicle screw instrumentation: Critical appraisal of current "State-of-Art"Neurology India, 2009
- Pedicle Screw Placement AccuracySpine, 2007
- Anatomy of the Thoracic PedicleNeurosurgery, 1995
- Accuracy of Pedicular Screw Placement In VivoSpine, 1990