Reliability of capturing foot parameters using digital scanning and the neutral suspension casting technique
Open Access
- 1 January 2011
- journal article
- Published by Wiley in Journal of Foot and Ankle Research
- Vol. 4 (1) , 9
Abstract
Background: A clinical study was conducted to determine the intra and inter‐rater reliability of digital scanning and the neutral suspension casting technique to measure six foot parameters. The neutral suspension casting technique is a commonly utilised method for obtaining a negative impression of the foot prior to orthotic fabrication. Digital scanning offers an alternative to the traditional plaster of Paris techniques.Methods: Twenty one healthy participants volunteered to take part in the study. Six casts and six digital scans were obtained from each participant by two raters of differing clinical experience. The foot parameters chosen for investigation were cast length (mm), forefoot width (mm), rearfoot width (mm), medial arch height (mm), lateral arch height (mm) and forefoot to rearfoot alignment (degrees). Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI) were calculated to determine the intra and inter‐rater reliability. Measurement error was assessed through the calculation of the standard error of the measurement (SEM) and smallest real difference (SRD).Results: ICC values for all foot parameters using digital scanning ranged between 0.81‐0.99 for both intra and inter‐rater reliability. For neutral suspension casting technique inter‐rater reliability values ranged from 0.57‐0.99 and intra‐rater reliability values ranging from 0.36‐0.99 for rater 1 and 0.49‐0.99 for rater 2.Conclusions: The findings of this study indicate that digital scanning is a reliable technique, irrespective of clinical experience, with reduced measurement variability in all foot parameters investigated when compared to neutral suspension casting.Keywords
This publication has 11 references indexed in Scilit:
- Reliabilty, smallest real difference and concurrent validity of indices computed from GRF components in gait of stroke patientsGait & Posture, 2009
- A Review of the Theoretical Unified Approach to Podiatric Biomechanics in Relation to Foot Orthoses TherapyJournal of the American Podiatric Medical Association, 2009
- Ability of Foot Care Professionals to Cast Feet Using the Nonweightbearing Plaster and the Gait-Referenced Foam Casting TechniquesJournal of the American Podiatric Medical Association, 2008
- Variability of Neutral-Position Casting of the FootJournal of the American Podiatric Medical Association, 2003
- A Comparison of Four Methods of Obtaining a Negative Impression of the FootJournal of the American Podiatric Medical Association, 2002
- Foot Orthosis Prescription Habits of Australian and New Zealand Podiatric PhysiciansJournal of the American Podiatric Medical Association, 2001
- Evaluation and Management of Foot and Ankle Disorders: Present Problems and Future DirectionsJournal of Orthopaedic & Sports Physical Therapy, 1995
- Comparison of Three Methods Used to Obtain a Neutral Plaster Foot ImpressionPhysical Therapy, 1989
- Functional hallux limitus and its relationship to gait efficiencyJournal of the American Podiatric Medical Association, 1986
- The continuing misinterpretation of the standard error of measurement.Psychological Bulletin, 1979