Sub-Surface Residual Stress Gradients: Advances in Laboratory XRD Methods
- 15 September 2006
- journal article
- conference paper
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 524-525, 25-30
Abstract
A new algorithm is proposed to determine the through-thickness residual stress gradient by X-ray Diffraction measurements on progressively thinned components. The procedure is based on a chemical or electrochemical attack of the component surface, which is then measured at each thinning stage. The simple algorithm provided for by a specific norm has been revised to take into account the X-ray absorption effects and the conditions of mechanical equilibrium of the component. The new procedure is illustrated for a typical case of study concerning a shot-peened metal component.Keywords
This publication has 4 references indexed in Scilit:
- Comparison of the hole-drilling and X-ray diffraction methods for measuring the residual stresses in shot-peened aluminium alloysThe Journal of Strain Analysis for Engineering Design, 2005
- Residual Strain Measurement by Synchrotron DiffractionMaterials Science Forum, 2002
- Non-destructive measurement of residual stress by neutron diffractionJournal of Materials Processing Technology, 2001
- Residual Stress1987